Omnitron Systems Technology 2FXM2 user manual CNode Loopback

Page 41

Once all the VLAN IDs have been assigned, select option 7 or 5 to save the entries.

PI

VLAN Membership - iConverter 2FXM2

 

iConverter, Serial Agent

Identifier -

 

 

 

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8959N-0

 

 

VLAN ID (VID)

Port 1

Port 2

BP A

BP B

Mngmnt

1:

100

 

Yes

No

No

No

No

Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

The VLAN membership entries are saved from the Port configuration screen, option 4.

4.3.10cNode Loopback

The 2FXM2 has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agent recognizes measurement packets and loops them back to the sending cNode device. Iometrix cNode equipment is required to obtain performance metrics.

cNode configuration is accessed by selecting option 10 from the Port configuration screen.

PI

SA

cNode Control -iConverter 2FXM2

iConverter, Serial Agent

Identifier -

 

 

Chassis Number = 1

Slot Number = 2

Model Number = 8959N-0

1:

cNode

Loopback

Disabled

2:

cNode

Rate Limit

64 Kbps

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

From the menu, loopback can be enabled or disabled and the rate limit can be selected.

Page 41

Image 41
Contents Standalone and PLUG-IN Module Table of Contents Plug-In OverviewPort Structure B B B B B B B Installation ProcedureThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan Pvid BP BVlan Table is Empty Vlan ID VIDBP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 2FXM2 SpecificationsPossible Causes Troubleshooting GuideLimitation of Warranty Warranty