Omnitron Systems Technology 2FXM2 user manual SFP Information

Page 29

4.3.4SFP Information

The 2FXM2 module will provide general and specific information on the SFP. This information is best viewed with SNMP management software. The following is the information available:

4.3.4.1SFP A0 Information Display

This section displays fixed SFP Module information for the following areas.

•

Identifier Values

•

Extended Identifier

•

Connector Values

•

Transceiver Codes

•

Encoding Rules

•

Normal Bit Rate

•

Link Length

•

Vendor Name

•

Vendor OUI

•

Vendor Revision Number

•

Laser Wavelength

•

Options

•

Vendor Serial Number

•

Date Code

•

Diagnostic Monitoring Type

•

Enhanced Options

•SFF-8472 Compliance

4.3.4.2SFP A2 Information Display

This section displays decoded SFP data collected for the following statistics.

•

Measured Temperature

•

Measured Vcc

•

Measured Bias

•

Measured Tx Power

•

Measured Rx Power

•

Temperature High Alarm Setting

•

Temperature Low Alarm Setting

•

Temperature High Warning Setting

•

Temperature Low Warning Setting

•

Vcc High Alarm Setting

•

Vcc Low Alarm Setting

•

Vcc High Warning Setting

•

Vcc Low Warning Setting

•

Bias High Alarm Setting

•

Bias Low Alarm Setting

•

Bias High Warning Setting

•

Bias Low Warning Setting

•

Tx Power High Alarm Setting

•

Tx Power Low Alarm Setting

•

Tx Power High Warning Setting

•

Tx Power Low Warning Setting

•

Rx Power High Alarm Setting

•

Rx Power Low Alarm Setting

•

Rx Power High Warning Setting

•Rx Power Low Warning Setting

Page 29

Image 29
Contents Standalone and PLUG-IN Module Table of Contents Plug-In OverviewPort Structure B B B B B B B Installation ProcedureThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan Pvid BP BVlan Table is Empty Vlan ID VIDBP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 2FXM2 SpecificationsPossible Causes Troubleshooting GuideLimitation of Warranty Warranty