Omnitron Systems Technology 2FXM2 user manual 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX

Page 7

NOTE: DIP-switches marked Reserved must be kept in the Left (factory default) position.

3.2.1.5SW5 - Fiber Port 2 Full/Half Duplex “FDX/HDX”

When the DIP-switch is in the Full Duplex “FDX” position (factory default), the fiber port facilitates a connection that supports Full-Duplex operation. Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports only Half-Duplex.

3.2.1.6SW6, SW7, SW8 - Link Modes

These three DIP-switches configure the link mode settings. The following table details possible Link Mode DIP-switch configurations.

PI

SA

SW6

SW7

SW8

Result

 

 

 

 

Left

Left

Left

Link Segment mode (LS)

 

 

 

 

Right

Left

Left

Link Propagate mode (LP)

 

 

 

 

Left

Right

Left

Remote Fault Detection mode plus Link

Segment mode (RFD+LS)

 

 

 

Right

Right

Left

Remote Fault Detection mode plus Link

Propagation mode (RFD+LP)

 

 

 

Left

Left

Right

Symmetrical Fault Detect mode (SFD)

 

 

 

 

Right

Left

Right

Asymmetrical LP P1 to P2 (ALP P1-P2)

 

 

 

 

Left

Right

Right

Asymmetrical LP P2 to P1 (ALP P2-P1)

 

 

 

 

Right

Right

Right

Asymmetrical RFD+LP P1 to P2

 

 

 

 

SW6

SW7

SW8

Result

 

 

 

 

Down

Down

Down

Link Segment mode (LS)

 

 

 

 

Up

Down

Down

Link Propagate mode (LP)

Down

Up

Down

Remote Fault Detection mode plus Link

 

 

 

Segment mode (RFD+LS)

Up

Up

Down

Remote Fault Detection mode plus Link

 

 

 

Propagation mode (RFD+LP)

Down

Down

Up

Symmetrical Fault Detect mode (SFD)

 

 

 

 

Up

Down

Up

Asymmetrical LP P1 to P2 (ALP P1-P2)

 

 

 

 

Down

Up

Up

Asymmetrical LP P2 to P1 (ALP P2-P1)

 

 

 

 

Up

Up

Up

Asymmetrical RFD+LP P1 to P2

 

 

 

 

NOTE: Connecting two converters set to any of the RFD modes are illegal and will cause a “deadly embrace” lockup.

NOTE: It is recommended to keep the LS setting (default) until initial configuration is complete.

For detailed information on the operation of the different Link Modes, download the application note “iConverter Link Modes” available on Omnitron’s web page:

http://www.omnitron-systems.com/downloads.php

Page 7

Image 7
Contents Standalone and PLUG-IN Module Table of Contents Plug-In OverviewPort Structure B B B B B B B Installation ProcedureThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan Pvid BP BBP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 2FXM2 SpecificationsPossible Causes Troubleshooting GuideLimitation of Warranty Warranty