Liebert GXT2-6000 RT208 user manual Specifications, UPS specifications

Page 47

Specifications

14.0SPECIFICATIONS

Table 8

UPS specifications

 

 

 

 

 

Model Number

GXT2-6000RT208

 

 

4200W/5200VA at 127/220 (120 or 240 degrees only)

 

 

4200W/5200VA at 120/208 (120 or 240 degrees)

 

Model Rating

4200W/6000VA at 120/240 (180 degrees)

 

4200W/6000VA at 115/230 (180 degrees only)

 

 

 

 

3780W/5400VA at 110/220 (180 degrees only)

 

 

3360W/4800VA at 100/200 (180 degrees only)

DIMENSIONS in (mm)

 

 

Unit W x D x H in. (mm)

6.9 x 24.2 x 16.9 (176 x 615 x 430)

 

Shipping W x D x H in. (mm)

13.2 x 27.8 x 20.9 (335 x 705 x 530)

WEIGHT lbs (kg)

 

 

Unit

67 (30.3)

 

Shipping

76.3 (34.6)

INPUT AC PARAMETERS

 

 

Nominal Operating Frequency

50 or 60 Hz (Factory Default = 60)

 

Factory Default VAC

120/208 VAC at 120 degrees

L1-L2 Factory Default Input Phase

120 degrees

 

Angle

 

 

 

Allowable Input Phase Angle

120, 180, 240 degrees, Auto-sensing on application of AC

 

(Restrictions for L-N voltages other than 120 VAC)

 

 

Factory Default L1-N, L2-N VAC

120 VAC nominal

User Configurable L1-N, L2-N VAC

100/110/115/120/127 VAC (May be modified using configuration program)

L1-N, L2-N, Operating Voltage Range

Without Battery Operation (Except 100 VAC L-N Operation)

 

100% - 90% loading

90 VAC - 140 VAC

 

90% - 70% loading

80 VAC - 140 VAC

 

70% - 30% loading

70 VAC - 140 VAC

 

30% - 0% loading

60 VAC - 140 VAC

L1-N, L2-N, Operating Voltage Range

Without Battery Operation (100 VAC L-N Operation)

 

100% - 70% loading

80 VAC - 140 VAC

 

70% - 30% loading

70 VAC - 140 VAC

 

30% - 0% loading

60 VAC - 140 VAC

L1-N, L2-N Max. Allowable VAC

150 VAC

 

Input Frequency w/o Battery

40 - 70 Hz

 

Operation

 

 

Input Power Connection

See Distribution Box Options

OUTPUT AC PARAMETERS

 

 

Factory Default VAC

120/208 VAC @ 120 degrees

 

L1-L2 Factory Default

120 degrees

 

Output Phase Angle

 

 

 

Allowable Output Phase Angle

120, 180, 240 degrees Auto-sensing on initial application of input AC

Factory Default L1-N, L2-N VAC

120 VAC nominal

User Configurable L1-N, L2-N VAC

100/110/115/120/127 VAC, ±3%

 

Output Connections

See Distribution Box Options

 

Frequency

50 Hz or 60 Hz, Nominal

 

Waveform

Sinewave

 

Main Mode Overload

200% for 8 cycles; 130% for 10 seconds with transfer to bypass

Bypass Protection Limits

 

 

Disable Bypass operation

If input voltage exceeds ±15% of the nominal voltage

 

Re-enable Bypass operation

If input voltage returns to within ±10% of nominal output voltage

 

Disable Bypass operation

When the input frequency prevents synchronous operation

41

Image 47
Contents GXT2-6000RT208 Power AvailabilityPage Table of Contents Controls and Indicators Configuration ProgramModes of Operation MaintenanceTroubleshooting SpecificationsFigures Important Safety Instructions Page Glossary of Symbols Introduction and System Description System Description Rectifier/Power Factor Correction PFC CircuitBattery Charger InverterDynamic Bypass BatteryDC to DC Converter Major Components Internal Battery PackMain Frame and Electronics PD-001 Removable Power Distribution BoxWHAT’S Included Top bezels Tower use Battery cover grilleGEC connector Mounting hardware Rack mount Handles Configuration Disk Ferrite BeadsAttach Bezels to Top Install the Main CabinetInstallation and Configuration Tower UPS InstallationReturn flanges Retaining Latches Front Innermembers members Installing the Adjustable Rack-Mount Kit-Sold SeparatelyQuantity Rack Depth M4 nuts M4 nutsExternal Battery Cabinet Installation Slide cover over connec- tors Loosen screws to move cover Connect Input/Output PowerReplacing a power distribution box Distribution Box Electrical ConnectionsElectrical requirements-PD-001 4 PD-001 Power Distribution BoxPD-HDWR and PD-HDWR-MBS Terminal Block Connections Electrical requirements-PD-HDWR and PD-HDWR-MBSGround Electrode System or Protective Earth System Install the Grounding Electrode ConductorInstall the Internal Battery Pack Initial Startup and Electrical Checks Initial Startup and Electrical Checks What You Will Need GXT2-6000RT208 Configuration Program FeaturesConfiguration Program Configuration Program-Installation Establishing Communication Link with the UPS Exit Without Changing UPS Settings Configuration Program-OperationRead/Confirm UPS Configuration Settings Changing UPS SettingsN Reverse Detection 120V UPS Models Only UPS TabOutput Voltage Auto RestartFrequency Selection Options TabOptions Tab Used With Earlier GXT 2U Models Battery Cabinets Number Battery TabLow Battery Time Warning Auto Battery Test TimeAbout Tab Horizontal overlay for rack mounting ON/Alarm Silence/Battery Test ButtonControls and Indicators OFF/Bypass ButtonUPS on Indicator Green Battery Level Indicators 5 GreenFault Indicator Red Bypass Indicator AmberModes of Operation Normal Mode OperationBattery Mode Operation Battery Recharge OperationCommunications Snmp Web Card Snmp Adapter Communications Interface PortCommunications 11.1.1 DB-9 Interface PortUPS Intelligent Communications Pin 4 Remote Shutdown on BatteryRepo Connection Remote Emergency Power OffKey to Repo switch connections 1 VDC Sense Ground Battery Cover Captive Screws Front Bezels Battery ReplacementMaintenance Internal Battery Replacement ProceduresConnector Connector cover Cover Electrical connectors UPS ReplacementIndicator status Diagnosis/Audible alarm TroubleshootingFault indicators Condition Alarm Alarm conditionsTroubleshooting guide Problem Cause Solution Only phase angles of 120, 180 or 240 degrees ±10 6000VA Run Time Battery run timesBattery/External Cabinets Load% Minutes Auto-Learning Battery Run Times UPS specifications SpecificationsModel Number Battery specificationsPower distribution box specifications See Battery run timesUsed w/ UPS Model GXT2-6000RT208 Dimensions in mm Product Warranty RegistrationExternal battery cabinet specifications Specifications Page Asia 23F, Allied Kajima Bldg Technical Support/ServiceCompany Behind the Products Locations