When operating as a slave, the SPI clock signal (SCLK) must be slower than 1/8th of the CPU clock (1/16th is recommended).
Note: The SPI is fully synchronous to the CLK signal. As a result, SCLK is sampled and then operated on. This results in a delay of 3 to 4 clocks, which may violate the SPI specification if SCLK is faster than 1/8th of the CPU clock. In master mode, the SPI operates exactly on the proper edges, since the SPI controller is generating SCLK.
The SPI controller uses a
The SPI interface includes the internal interrupt connection, SPI interrupt.
In SPI master mode, an SPI interrupt occurs when the Transmit Holding register is empty.
In SPI slave mode, an SPI interrupt occurs when the SLVSEL pin transitions from active to inactive.
A familiar Interrupt Control register is provided for the SPI interrupt. The interrupt has a two CPU clock delay from SLVSEL in slave mode because of synchronization registers.
SPI Controller Register Summary
Table 2-1. SPI Controller Register Summary
Hex Address | Mnemonic | Register Description | Page |
B800 | SPI_DATA | Data register | 6 | |
B802 | CTL | Control register |
| 7 |
B804 | SPI_STAT | Status register | 8 | |
B806 | SPI_SSEL | Slave Select Bit Count register |
| 9 |
B808 | DVD_CNTR_LO | DVD Counter Low Byte register | 10 | |
B80A | DVD_CNTR_HI | DVD Counter High Byte register |
| 10 |
|
|
|
|
|