Troubleshooting Checklist
Table 4-1 LANVIEW LEDs (Continued)
LED | Color | State | Recommended Action |
|
|
|
|
TX | Off | Port enabled, and no | 1. Ensure that the STA is enabled and that |
(Transmit) |
| activity. | there is a valid link. |
|
| Should flash green every | 2. Contact Enterasys Networks for |
|
| two seconds indicating | assistance. |
|
| BPDUs being sent if STA |
|
|
| is enabled and there is a |
|
|
| valid link. |
|
|
|
|
|
| Green | Flashing. Indicates | None. |
|
| activity. Rate indicates |
|
|
| data rate. |
|
|
|
|
|
| Amber | Blinking. Port in | 1. Ensure that the port is not disabled. |
|
| standby. | 2. Contact Enterasys Networks for |
|
|
| |
|
| Port may be disabled due | assistance. |
|
| to Spanning Tree. |
|
|
|
|
|
| Red | Flashing. Indicates | None, unless there is a high amount of |
|
| collision rate. | activity. In this case, check for network |
|
|
| configuration problems or a defective |
|
|
| device. |
|
|
|
|
|
| Solid. Diagnostic failure. | Contact Enterasys Networks for assistance. |
|
|
|
|
4.2TROUBLESHOOTING CHECKLIST
If the
Table
Problem | Possible Cause | Recommended Action |
|
|
|
All LEDs are | Loss of power. | Check for proper connection of the power |
OFF. |
| cable and its access to a live outlet. |
|
|
|
| Installed improperly. | Ensure that the |
|
| properly according to the installation |
|
| instructions in Chapter 3. |
|
|
|