Cypress CYD02S36V manual Scan Chain for 18-Mbit Device, Scan Register Sizes Register Name Bit Size

Page 10

CYD01S36V

CYD02S36V/36VA/CYD04S36V

CYD09S36V/CYD18S36V

Figure 4. Scan Chain for 18-Mbit Device

 

TDO

TDO

TDO

D2

D4

TDI

TDI

TDO

TDO

D1

D3

TDI

TDI

TDI

 

 

Figure 5. Scan Chain for 9-Mbit Device

 

 

TDO

 

 

TDO

 

 

D2

 

 

TDI

 

 

TDO

 

 

D1

 

 

TDI

 

 

TDI

Table 4. Identification Register Definitions

 

Instruction Field

Value

Description

Revision Number (31:28)

 

0h

Reserved for version number.

Cypress Device ID (27:12)

 

C002h

Defines Cypress part number for CYD04S36V, CYD09S36V and CYD18S36V

 

 

 

 

 

 

 

C001h

Defines Cypress part number for CYD02S36V/36VA

 

 

 

 

 

 

 

C092h

Defines Cypress part number for CYD01S36V

 

 

 

 

 

Cypress JEDEC ID (11:1)

 

034h

Allows unique identification of the DP family device vendor.

 

 

 

 

ID Register Presence (0)

1

Indicates the presence of an ID register.

 

 

 

Table 5. Scan Register Sizes

 

 

 

 

 

 

Register Name

 

Bit Size

 

Instruction

 

4

 

 

 

 

 

Bypass

 

1

 

 

 

Identification

 

32

 

 

 

Boundary Scan

 

n[24]

Note

24. See details in the device BSDL files.

Document Number: 38-06076 Rev. *G

Page 10 of 28

[+] Feedback

Image 10
Contents Functional Description FeaturesSeamless Migration to Next-Generation Dual-Port Family Logic Block Diagram1 Dual Ported ArrayPin Configurations DQ10R DQ12R DQ14RPin Definitions Mailbox Interrupts Master ResetAddress Counter and Mask Register Operations19 CLK Mrst CNT/MSK Cntrst ADS Cnten Counter Reset OperationCounter Load Operation Operation DescriptionCounter Hold Operation Mask Reset OperationCounter Increment Operation Counter InterruptCounter, Mask, and Mirror Logic Block Diagram1 Performing a Pause/Restart Performing a TAP ResetIeee 1149.1 Serial Boundary Scan JTAG23 Boundary Scan Hierarchy for 9-Mbit and 18-Mbit DevicesScan Chain for 18-Mbit Device Scan Register Sizes Register Name Bit SizeInstruction Identification Codes Description ReservedOperating Range Electrical Characteristics Over the Operating RangeMaximum Ratings CapacitanceSwitching Characteristics Over the Operating Range Jtag Timing Port to Port DelaysMaster Reset Timing Parameter Description 167/133/100 Unit MinJtag Switching Waveform Switching WaveformsAddress CLKData OUT Address B2 ADDRESSB1Data OUT Read No Operation Write Read Write DatainDataout ADSAddress Internal ADS CntenRead Reset Address Counter WriteCLK External Address A0-A16 Internal Address Load Readback Increment External Counter Address InternalLport Data CLK LLport CLK RCounter Interrupt and Retransmit17, 45, 53, 54, 55 CNT/MSK ADS Cnten Counter Internal 3FFFC 3FFFD 3FFFE 3FFFFLport 7FFFF Address CLK CE0 CE1Clkl INT ROrdering Information Package Diagrams Ball Fbga 17 x 17 mm BB256Ball Fbga 23 mm x 23 mm x 1.7 mm BB256B Document History Sales, Solutions and Legal InformationWorldwide Sales and Design Support Products PSoC Solutions REV ECN no