Briggs & Stratton 71008, 71010, 71009, 71011 manual Troubleshooting, Problem Cause Correction

Page 12

TROUBLESHOOTING

TROUBLESHOOTING

Problem

Cause

Correction

Automatic transfer switch does

1.

Generator breaker open.

1.

Reset generator circuit breaker.

not transfer to generator

2.

Generator voltage not acceptable.

2.

Refer to generator manual.

 

 

 

 

 

 

1.

Utility disconnect breaker open

1.

Reset utility disconnect breaker

Automatic transfer switch does

 

(Models 071010 & 071011 only).

 

(Models 071010 & 071011 only).

2.

Service disconnect breaker open.

2.

Reset service disconnect breaker.

not transfer to utility

3.

Utility voltage not acceptable.

3.

Wait for utility voltage to return to

 

 

 

 

 

normal.

 

 

 

Generator is still running after

Engine cool down period.

Engine should stop after 1 minute.

switch transfers to utility power

 

 

 

 

 

 

 

 

 

 

1.

A-A or B-B contacts not operating

1.

Check A-A or B-B contacts for

 

 

correctly.

 

proper operation and/or check

Supervised loads (air conditioner,

 

 

 

control wiring to external load.

2.

Too much load on generator.

2.

Decrease load to generator.

etc.) are not operating when

3.

Current transformer not

3.

Contact local Briggs & Stratton

generator is supplying power

 

connected.

 

Power Products service center.

 

 

 

 

4.

Broken current transformer.

4.

Contact local Briggs & Stratton

 

 

 

 

Power Products service center.

 

 

 

 

 

 

1.

Minimum engine run time has not

1.

Wait five minutes for transfer

Generator is still running after

 

elapsed.

 

switch to retransfer to utility

 

 

 

power.

utility power is restored

 

 

 

2.

Fuse(s) in transfer switch is

2.

Check fuse(s) and replace if

 

 

 

defective.

 

necessary.

 

 

 

 

 

12

Image 12
Contents Installation Operator’s Manual Commutateur deTransfertTable of Contents Important Safety Instructions Safety InstructionsOnly qualified electricians should attempt installation For the Installing Dealer/Contractor IntroductionFor the Home Owner IntroductionInstaller Responsibilities Owner OrientationEquipment Description Installation InstallationUnpacking Mounting GuidelinesTypical Transfer Switch Mounting for Models 071010 Power Wiring Interconnections Supervisory Control WiringSystem Setup Typical Installation Diagram for Transfer SwitchTesting the Automatic Transfer Switch When Calling the FactorySystem Operation Automatic SequenceSpecifications SpecificationsUL 1008 Listed Transfer Switch Model Troubleshooting TroubleshootingProblem Cause Correction Page Schematic and Wiring Diagram Schematic and Wiring DiagramModels 071010 Transfer Switch Exploded View & Parts List Exploded View and Parts ListDescription Items Not IllustratedDECAL, 200A,ATS LOCKWASHER, #10 BUS BAR Page Limited Warranty Table DES Matières Table DES MatièresAvertissement Directives DE Sécurité ImportantesAu Détaillant ou à lEntrepreneur Procédant à lInstallation IntroductionAu Propriétaire Résidentiel Responsabilités de lInstallateur Conseils au PropriétaireDescription de lÉquipement Installation Consignes dinstallationDéballage Vérification de la LivraisonUne installation alternative du commutateur de transfert Interconnexions du câblage dalimentation Câblage de contrôleConfiguration du système Schéma dInstallation Typique du Commutateur de TransfertFonctionnement Mise À Lessai DU Commutateur DE Transfert AutomatiqueFonctionnement Séquence AutomatiqueCaractéristiques CaractéristiquesUL 1008 Enuméré Commutateur de Transfert Modéle ModèleDépannage DépannageGarantie Limitée Tabla DE Contenido Tabla DE ContenidoAdvertencia PrecauciónReglas DE Seguridad Introducción IntroducciónPara el Propietario Doméstico Orientación para el Propietario Responsabilidades del InstaladorDescripción del Equipo Instalación DesempaqueInstalación Pautas de MontajeFigura 17 Montaje de un Conectador Alternativo Interconexiones de Cableado de Energía Cableado de Control de SupervisiónConfiguración del Sistema Figura 21 Módulo de controlSistema Funcionamiento Prueba DEL Conectador AutomáticoFuncionamiento Secuencia AutomáticaProblemo Causa Accion EspecificacionesReparacion DE Averias Especificaciones Y Reparacion DE AveriasGarantía Limitada