Briggs & Stratton 71010 Owner Orientation, Installer Responsibilities, Equipment Description

Page 5

INTRODUCTION

Owner Orientation

The illustrations are for typical circumstances and are meant to familiarize you with the installation options available with your transfer switch.

Local codes, appearance, and distances are the factors that must be considered when negotiating with an installation professional. As the distance from the existing electrical service increases, compensation in wiring materials must be allowed for.This is necessary to comply with local codes and overcome electrical voltage drops.

The factors mentioned above will have a direct effect on the overall price of your transfer switch installation.

NOTE: Your installer must check local codes AND obtain permits before installing the system.

Read and follow the instructions given in this manual.

Follow a regular schedule in caring for and using your transfer switch, as specified in the manual.

Installer Responsibilities

Read and observe the safety rules.

Read and follow the instructions given in this manual.

Check federal, state and local codes.

Ensure generator is not overloaded with selected loads.

Equipment Description

The transfer switches are intended to transfer the entire load of normal residential installations when used with the supervisory contacts provided.The load is connected either to utility power (normal) or home standby power (generator).The transfer switch monitors utility and generator voltages and will automatically connect to the appropriate source of power.

Major components of the transfer switch are a 2 pole utility disconnect circuit breaker (models 071010 & 071011 only), a 2 pole double throw transfer switch, control circuit board, fused utility terminals and interconnecting wiring. The control board also has two inputs for current transformers that sense generator current.

The transfer switch is solenoid-operated from utility or generator inputs and contain suitable mechanical and electrical interlock switches to eliminate the possibility of connecting the utility service to the generator output. It has ratings capable of switching full utility power into the residence. In addition, a manual override lever is provided for the transfer function.

The control circuit board has active circuits sensing utility and generator voltages. It creates a signal for the generator start-up, switch transfer and retransfer when utility is restored.The control board also contains red and green LED’s indicating the power sources available and two relay operated contacts that provide supervisory control of external loads.

5

Image 5
Contents Commutateur deTransfert Installation Operator’s ManualTable of Contents Only qualified electricians should attempt installation Important Safety InstructionsSafety Instructions Introduction For the Installing Dealer/ContractorFor the Home Owner IntroductionEquipment Description Installer ResponsibilitiesOwner Orientation Installation InstallationUnpacking Mounting GuidelinesTypical Transfer Switch Mounting for Models 071010 Supervisory Control Wiring Power Wiring InterconnectionsTypical Installation Diagram for Transfer Switch System SetupWhen Calling the Factory Testing the Automatic Transfer SwitchSystem Operation Automatic SequenceUL 1008 Listed Transfer Switch Model SpecificationsSpecifications Problem Cause Correction TroubleshootingTroubleshooting Page Schematic and Wiring Diagram Schematic and Wiring DiagramModels 071010 Exploded View and Parts List Transfer Switch Exploded View & Parts ListDescription Items Not IllustratedDECAL, 200A,ATS LOCKWASHER, #10 BUS BAR Page Limited Warranty Table DES Matières Table DES MatièresDirectives DE Sécurité Importantes AvertissementAu Propriétaire Résidentiel Au Détaillant ou à lEntrepreneur Procédant à lInstallationIntroduction Description de lÉquipement Responsabilités de lInstallateurConseils au Propriétaire Consignes dinstallation InstallationDéballage Vérification de la LivraisonUne installation alternative du commutateur de transfert Câblage de contrôle Interconnexions du câblage dalimentationSchéma dInstallation Typique du Commutateur de Transfert Configuration du systèmeMise À Lessai DU Commutateur DE Transfert Automatique FonctionnementFonctionnement Séquence AutomatiqueCaractéristiques CaractéristiquesUL 1008 Enuméré Commutateur de Transfert Modéle ModèleDépannage DépannageGarantie Limitée Tabla DE Contenido Tabla DE ContenidoReglas DE Seguridad AdvertenciaPrecaución Para el Propietario Doméstico IntroducciónIntroducción Descripción del Equipo Orientación para el PropietarioResponsabilidades del Instalador Desempaque InstalaciónInstalación Pautas de MontajeFigura 17 Montaje de un Conectador Alternativo Cableado de Control de Supervisión Interconexiones de Cableado de EnergíaFigura 21 Módulo de control Configuración del SistemaPrueba DEL Conectador Automático Sistema FuncionamientoFuncionamiento Secuencia AutomáticaEspecificaciones Problemo Causa AccionReparacion DE Averias Especificaciones Y Reparacion DE AveriasGarantía Limitada