RAD Data comm operation manual Operating RIC-E1, Connecting the Cables, To connect cables

Page 12

 

Quick Start Guide

 

RIC-E1Installation and Operation Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper

Description

Values

Default Setting

 

 

 

 

 

 

 

JP2, JP3

Select the E1 interface type

BALANCE – Balanced interface

BALANCE

 

 

 

(RJ-45 connector)

 

 

 

 

 

UNBALANCE – Unbalanced

 

 

 

 

 

interface (BNC

 

 

 

 

 

coax connectors)

 

 

 

 

 

 

 

 

 

ALB DTE, JP4

Enables local analog

EN – The local analog loopback

 

 

 

 

loopback activation from

activation from the DTE is

 

 

 

 

the DTE (via pin 18 for

enabled

 

 

 

 

RS-530 or via pin “JJ” for

DIS – The local analog loopback

DIS

 

 

V.35)

activation from the DTE is

 

 

disabled

Note: The JP4 jumper is not available for RIC-E1/R cards with X.21 or Ethernet interfaces.

PNL SW, JP5

Enables activation of the

 

local analog loopback via

 

the front panel pushbutton

EN – The LLB can be activated via EN the front panel

DIS – The LLB cannot be activated via the front panel

Note: The JP5 jumper is not available for RIC-E1/R cards with IR-ETH and IR-ETH/V interface modules.

For RIC-E1/R with IR-IP interface module, the JP5 jumper serves for enabling or disabling the IP LEARN pushbutton.

TX&RX CODE, JP6

Selects the data receive

HDB3

HDB3

 

and transmit coding

AMI

 

 

 

 

 

TIMING SEL, J2

Selects the clock reference

RCV – Receive clock

RCV

 

 

EXT – External clock

 

 

 

INT – Internal clock

 

Note: Units with the IR-ETH, IR-ETH/V and IR-IP interface modules support only receive and internal clocks.

CHASS GND, J3 Controls the connection between the RIC-E1/R signal ground and the frame (chassis) ground

CON – Signal ground is

CON

connected to the frame

 

ground

 

DISCON – Signal ground is

 

disconnected from the

 

frame ground

 

Connecting the Cables

To connect cables:

1.Connect the E1 line interface.

2.Connect the DTE interface.

3.Connect the power cable (first to the converter, then to the mains supply). The PWR LED lights when power is connected.

2.Operating RIC-E1

RIC-E1 operates entirely unattended except when performing system tests.

2

Operating RIC-E1

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Image 12
Contents RIC-E1 Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 RIC-E1 International Headquarters RAD Data Communications IncLimited Warranty General Safety Instructions Please observe the following precautionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Ports Safety Status IsdnElectromagnetic Compatibility EMC Canadian Emission Requirements Safety Manufacturers Name Manufacturers AddressProduct Names Supplementary InformationInstalling RIC-E1 Setting the Internal JumpersJumper Description Values Default Setting Quick Start GuideConnecting the Cables Operating RIC-E1To connect cables Contents List of Figures Power Supply Chapter IntroductionOverview VersionsPhysical Description ApplicationFunctional Block Diagram DiagnosticsFunctional Description Timing ReferenceTechnical Specifications Receive, derived from the received signalDerived from three alternative sources Internal oscillatorDiagnostics PowerPhysical EnvironmentTechnical Specifications Chapter Installation and Setup Package ContentsSite Requirements and Prerequisites Configuring RIC-E1 Setting the JumpersTo install RIC-E1 To set the jumpersRIC-E1 Jumper Locations RIC-E1 Jumper Settings Connecting the Interfaces Connecting the E1 LineSelecting the Impedance Closing the RIC-E1 CaseConnecting the Power Connecting the DTEConnecting the AC Power Connecting the DC PowerInstallation and Setup Front Panel Indicators Chapter OperationDesignation Color Function Operating Instructions Turning OnOperating RIC-E1 Turning OffChapter Troubleshooting Diagnostics Performing Local Analog LoopbackActivating Local Analog Loopback Troubleshooting RIC-E1 TroubleshootingDeactivating Local Analog Loopback To activate the local analog loopback from RIC-E1/RTechnical Support Technical Support Line Connector DTE ConnectorChapter RIC-E1/R Card ASM-MN-214 Card CageASM-MN-214 Rear Panel Power Supply Power Supply with RedundancyAC Supply DC SupplyRIC-E1/R Front Panel IR-ETH or IR-ETHASM-MN-214 Front Panel Installing the RIC-E1/R Card Setting Internal Jumpers and SwitchesRIC-E1/R PCB Layout RIC-E1/R Jumper Settings Installing RIC-E1/R into the ASM-MN-214 Card Cage To install the RIC-E1/R card in the ASM-MN-214 card cageRIC-E1/R Card Appendix a Interface Connector Wiring V.35, X.21 and RS-530 Interface ConnectorsV.36 Interface Connector Signal Function 36, 37-Pin RS-530, 25-pin CircuitLine Interface Connector Table A-3. RJ-45 Line Interface Connector, Pin AssignmentSignal Function 36, 37-pin RS-530, 25-pin Pin Circuit Pin FunctionAppendix a Interface Connector Wiring Contents Appendix B IR-ETH Interface ModuleIntroduction IR-ETH Options Standalone RIC-E1RIC-E1/R Card Table B-1. RJ-45 PinoutFigure B-3. RIC-E1/R with IR-ETH Installation and Operation Setting the DIP Switch LED IndicatorsTable B-2. DIP Switch Settings Connecting the LAN Table B-4. IR-ETH LED Indicators, RIC-E1/RLink ACTAppendix C IR-ETH/V Interface Module IR-ETH/V Options RIC-E1 For example, MDI in OFF position, MDI is enabled Mbps full duplex, 285 ∝sThroughput Data 00, 01, 02, …Setting the DIP Switches Table C-2. DIP SW1 Switch SettingsMoved by the user Table C-3. DIP Switch SW2 Settings Section Name Description Possible Settings Factory SettingTable C-4. IR-ETH/V LED Indicators Backpressure and Flow ControlColor Function Appendix D IR-IP Interface Module IntroductionAppendix D IR-IP Interface Module Connector 10BaseT Shielded RJ-45 Standard Ieee 802.3/Ethernet Data RateProtocols Frame Relay RFCRIC-E1/ IP IR-IP LEDs IR-IP ControlsTable D-1. IR-IP LEDs Functions Standalone RIC-E1 Table D-2. IR-IP LEDs Functions RIC-E1/R CardControl Function Values Default Setting IR-IP Management Subsystem, GeneralTable D-3. IR-IP Controls Table D-4 RJ-45 PinoutAccessing the IR-IP Management Subsystem Default IP Communication ParametersPerforming Preliminary Configuration Rescue ConfigurationOutline of Preliminary Configuration To allow the IR-IP configurationConnecting the Telnet Host Preliminary Telnet Host ConfigurationAssigning the Router LAN Interface Address IP Learning MechanismTo view and edit the ARP table contents To configure the IP router LAN addressAssigning a LAN IP Address to a New IR-IP Changing the LAN IP Address of a Configured IR-IP After RIC-E1 is turned on, the ERR indicator does not lightWhat to Do If No ping replies from IR-IPGeneral Operating Procedures IR-IP Management UtilityStarting a Management Utility Quick Setup Menu To access the Quick Setup menuMenu Structure of Management Utility Default Gateway LAN IP AddressLAN IP Mask WAN IP AddressRead Protocol from DIP Switches Operation with Default GatewayTo configure the IR-IP as a Dhcp relay Dhcp RelayManagement Access Menu Telnet PasswordTo access the Management Access menu ProtocolAdvanced Setup Menu Telnet Inactivity TimeoutTo access the Advanced Setup menu To access the Device Identification menuTo access the Interface Parameters menu Interface Parameters MenuDevice Name Contact PersonWAN Protocol Parameters Frame Relay Protocol Menu Authentication Protocol WAN Protocol Parameters PPP ProtocolHeader and Control Field Compression Protocol Field CompressionMulticast IP Multicast Forwarding Figure D-17. Multicast IP MenuTo access the Device Control menu Device ControlStatic Groups Viewing Error Log Screen New Software Download MenuErasing Configuration Resets MenuResetting the Device Resetting the LAN InterfaceConfiguration and Connection To access the View menuTo access the Configuration and Connection screen View MenuTo access the ARP Tables screen ARP TablesTo access the Multicast Groups Table screen To access the Statistics menuMulticast Groups Table Screen Displaying StatisticsDiagnostic Tools Ping Terminal To access the Diagnostic Tools menuUsing the Ping Function To ping a hostErasing User’s Configuration To erase the user’s configurationErasing IR-IP Software Desired positions, and then turn the RIC-E1 on againErasing Application Software Downloading New SoftwareTo erase the application software Case, it is recommended to turn RIC-E1 off and then back onAppendix D IR-IP Interface Module Appendix E IR-X.21B Interface Module Rear PanelEXT Clock Mode Selecting the IR-X.21B TimingINT/LBT Clock Mode IR-X.21BBuffer Appendix E IR-X.21B Interface Module Impedance, 2-4Indicators IndexIP-IR IR-ETHIR-IP LEDRequirements, 2-1RIC-E1/R Card Customer Response Form Excellent Good Fair Poor Very PoorError Report Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters