RAD Data comm RIC-E1 Connecting the Telnet Host, Preliminary Telnet Host Configuration

Page 65

RIC-E1Installation and Operation Manual

Appendix D IR-IP Interface Module

 

 

Connecting the Telnet Host

Before starting the management and configuration activities, it is necessary to establish IP communication between your Telnet host and the IR-IP interface module. For this purpose, it is necessary to provide a communication path.

Because of the method used to assign an IP address to IR-IP Ethernet port, it is recommended to connect the Telnet host directly to the IP router 10BASE-T connector. This is made by connecting an Ethernet cross cable between the Ethernet connector of the Telnet host and the IP router connector.

However, you may also connect through a common LAN: in this case, connect your Telnet host and IR-IP to Ethernet hub ports using straight cables.

Preliminary Telnet Host Configuration

You can use the IP learning mechanism to configure the IP communication parameters of the IR-IP LAN interface. In this case, skip to the Assigning the Router LAN Interface Address section below.

If you prefer to use the factory-default parameters to establish IP communication between your Telnet host and IR-IP, configure the Telnet host as follows:

1.Temporarily configure the host IP address as 192.168.205.2.

2.The initial destination IP address to be used by the host is 192.168.205.1.

Note The first step in the preliminary configuration process is to assign the desired IP address to the LAN interface of the IR-IP interface module.

After an IP address is assigned and saved, you must change the destination IP address of the Telnet host to the new address, otherwise it is not possible to continue the configuration process. At the same time, you can also change the temporary IP address assigned to the host (192.168.205.2) back to its permanent address.

Assigning the Router LAN Interface Address

The IP address of the IR-IP LAN interface must be configured as part of the preliminary configuration process. To simplify this process, IR-IP includes a simple and convenient IP address learning mechanism.

The IP address can be configured and changed at any time, even after the complete IR-IP configuration process has been performed, because it does not affect other configuration parameters. Moreover, the IP subnet mask is automatically adapted to the new IP address.

IP Learning Mechanism

To simplify the configuration process, IR-IP has a special mechanism for configuring the IP address of its LAN interface. Setting section 1, called IP address learning, of the IR-IP DIP switch (Figure D-4)to ON enables this mechanism.

For RIC-E1/R the IP learning procedure is performed by pressing the IP LEARN pushbutton on the card panel.

The IP learning mechanism enables IR-IP to learn its LAN interface IP address by receiving frames sent by a ping utility to the prescribed LAN IP address.

Note

 

 

To use the IP learning mechanism, you do not need to know the current address of

 

 

IR-IP LAN interface, but only the prescribed IP address.

 

 

 

 

 

Performing Preliminary Configuration

D-9

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Image 65
Contents RIC-E1 Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters RAD Data Communications Inc RIC-E1Limited Warranty Please observe the following precautions General Safety InstructionsConnection of DC Mains General Safety PracticesConnection of AC Mains Isdn Ports Safety StatusElectromagnetic Compatibility EMC Canadian Emission Requirements Manufacturers Name Manufacturers Address SafetyProduct Names Supplementary InformationSetting the Internal Jumpers Installing RIC-E1Jumper Description Values Default Setting Quick Start GuideTo connect cables Connecting the CablesOperating RIC-E1 Contents List of Figures Chapter Introduction Power SupplyOverview VersionsApplication Physical DescriptionDiagnostics Functional Block DiagramFunctional Description Timing ReferenceReceive, derived from the received signal Technical SpecificationsDerived from three alternative sources Internal oscillatorPower DiagnosticsPhysical EnvironmentTechnical Specifications Site Requirements and Prerequisites Chapter Installation and SetupPackage Contents Setting the Jumpers Configuring RIC-E1To install RIC-E1 To set the jumpersRIC-E1 Jumper Locations RIC-E1 Jumper Settings Connecting the E1 Line Connecting the InterfacesSelecting the Impedance Closing the RIC-E1 CaseConnecting the DTE Connecting the PowerConnecting the AC Power Connecting the DC PowerInstallation and Setup Designation Color Function Front Panel IndicatorsChapter Operation Turning On Operating InstructionsOperating RIC-E1 Turning OffActivating Local Analog Loopback Chapter Troubleshooting DiagnosticsPerforming Local Analog Loopback RIC-E1 Troubleshooting TroubleshootingDeactivating Local Analog Loopback To activate the local analog loopback from RIC-E1/RTechnical Support Technical Support DTE Connector Line ConnectorChapter RIC-E1/R Card ASM-MN-214 Card CageASM-MN-214 Rear Panel Power Supply with Redundancy Power SupplyAC Supply DC SupplyIR-ETH or IR-ETH RIC-E1/R Front PanelASM-MN-214 Front Panel RIC-E1/R PCB Layout RIC-E1/R Jumper Settings Installing the RIC-E1/R CardSetting Internal Jumpers and Switches To install the RIC-E1/R card in the ASM-MN-214 card cage Installing RIC-E1/R into the ASM-MN-214 Card CageRIC-E1/R Card V.35, X.21 and RS-530 Interface Connectors Appendix a Interface Connector WiringSignal Function 36, 37-Pin RS-530, 25-pin Circuit V.36 Interface ConnectorTable A-3. RJ-45 Line Interface Connector, Pin Assignment Line Interface ConnectorSignal Function 36, 37-pin RS-530, 25-pin Pin Circuit Pin FunctionAppendix a Interface Connector Wiring Introduction ContentsAppendix B IR-ETH Interface Module Standalone RIC-E1 IR-ETH OptionsRIC-E1/R Card Table B-1. RJ-45 PinoutFigure B-3. RIC-E1/R with IR-ETH Installation and Operation Table B-2. DIP Switch Settings Setting the DIP SwitchLED Indicators Table B-4. IR-ETH LED Indicators, RIC-E1/R Connecting the LANLink ACTAppendix C IR-ETH/V Interface Module IR-ETH/V Options RIC-E1 Mbps full duplex, 285 ∝s For example, MDI in OFF position, MDI is enabledThroughput Data 00, 01, 02, …Table C-2. DIP SW1 Switch Settings Setting the DIP SwitchesMoved by the user Table C-3. DIP Switch SW2 Settings Section Name Description Possible Settings Factory SettingColor Function Table C-4. IR-ETH/V LED IndicatorsBackpressure and Flow Control Introduction Appendix D IR-IP Interface ModuleAppendix D IR-IP Interface Module Standard Ieee 802.3/Ethernet Data Rate Connector 10BaseT Shielded RJ-45Protocols Frame Relay RFCRIC-E1/ IP IR-IP Controls IR-IP LEDsTable D-1. IR-IP LEDs Functions Standalone RIC-E1 Table D-2. IR-IP LEDs Functions RIC-E1/R CardIR-IP Management Subsystem, General Control Function Values Default SettingTable D-3. IR-IP Controls Table D-4 RJ-45 PinoutDefault IP Communication Parameters Accessing the IR-IP Management SubsystemRescue Configuration Performing Preliminary ConfigurationOutline of Preliminary Configuration To allow the IR-IP configurationPreliminary Telnet Host Configuration Connecting the Telnet HostAssigning the Router LAN Interface Address IP Learning MechanismAssigning a LAN IP Address to a New IR-IP To view and edit the ARP table contentsTo configure the IP router LAN address After RIC-E1 is turned on, the ERR indicator does not light Changing the LAN IP Address of a Configured IR-IPWhat to Do If No ping replies from IR-IPStarting a Management Utility General Operating ProceduresIR-IP Management Utility Menu Structure of Management Utility Quick Setup MenuTo access the Quick Setup menu LAN IP Address Default GatewayLAN IP Mask WAN IP AddressOperation with Default Gateway Read Protocol from DIP SwitchesTo configure the IR-IP as a Dhcp relay Dhcp RelayTelnet Password Management Access MenuTo access the Management Access menu ProtocolTelnet Inactivity Timeout Advanced Setup MenuTo access the Advanced Setup menu To access the Device Identification menuInterface Parameters Menu To access the Interface Parameters menuDevice Name Contact PersonWAN Protocol Parameters Frame Relay Protocol Menu WAN Protocol Parameters PPP Protocol Authentication ProtocolHeader and Control Field Compression Protocol Field CompressionMulticast IP Figure D-17. Multicast IP Menu Multicast ForwardingStatic Groups To access the Device Control menuDevice Control New Software Download Menu Viewing Error Log ScreenResets Menu Erasing ConfigurationResetting the Device Resetting the LAN InterfaceTo access the View menu Configuration and ConnectionTo access the Configuration and Connection screen View MenuARP Tables To access the ARP Tables screenTo access the Statistics menu To access the Multicast Groups Table screenMulticast Groups Table Screen Displaying StatisticsTo access the Diagnostic Tools menu Diagnostic Tools Ping TerminalTo ping a host Using the Ping FunctionTo erase the user’s configuration Erasing User’s ConfigurationErasing IR-IP Software Desired positions, and then turn the RIC-E1 on againDownloading New Software Erasing Application SoftwareTo erase the application software Case, it is recommended to turn RIC-E1 off and then back onAppendix D IR-IP Interface Module Rear Panel Appendix E IR-X.21B Interface ModuleSelecting the IR-X.21B Timing EXT Clock ModeBuffer INT/LBT Clock ModeIR-X.21B Appendix E IR-X.21B Interface Module Index Impedance, 2-4IndicatorsIP-IR IR-ETHRequirements, 2-1RIC-E1/R Card IR-IPLED Excellent Good Fair Poor Very Poor Customer Response FormError Report Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters