RAD Data comm RIC-E1 operation manual International Headquarters RAD Data Communications Inc

Page 3

RIC-E1

E1 Interface Converter

Installation and Operation Manual

Notice

This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications.

Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the RIC-E1 and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD.

RIC-E1 is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.

You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the RIC-E1. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the RIC-E1, based on or derived in any way from the RIC-E1. Your undertaking in this paragraph shall survive the termination of this Agreement.

This Agreement is effective upon your opening of the RIC-E1 package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the RIC-E1 and all copies and portions thereof.

For further information contact RAD at the address below or contact your local distributor.

 

International Headquarters

U.S. Headquarters

 

 

RAD Data Communications Ltd.

RAD Data Communications Inc.

 

 

24 Raoul Wallenberg St.

900 Corporate Drive

 

 

Tel Aviv 69719 Israel

Mahwah, NJ 07430 USA

 

 

Tel: 972-3-6458181

Tel: (201) 529-1100, Toll free: 1-800-444-7234

 

 

Fax: 972-3-6498250

Fax: (201) 529-5777

 

 

E-mail:market@rad.com

E-mail:market@radusa.com

 

 

 

 

 

© 1991–2003 RAD Data Communications Ltd.

Publication No. 269-200-12/04

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Image 3
Contents RIC-E1 Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters RAD Data Communications Inc RIC-E1Limited Warranty Please observe the following precautions General Safety InstructionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Isdn Ports Safety StatusElectromagnetic Compatibility EMC Canadian Emission Requirements Supplementary Information SafetyManufacturers Name Manufacturers Address Product NamesQuick Start Guide Installing RIC-E1Setting the Internal Jumpers Jumper Description Values Default SettingConnecting the Cables Operating RIC-E1To connect cables Contents List of Figures Versions Power SupplyChapter Introduction OverviewApplication Physical DescriptionTiming Reference Functional Block DiagramDiagnostics Functional DescriptionInternal oscillator Technical SpecificationsReceive, derived from the received signal Derived from three alternative sourcesEnvironment DiagnosticsPower PhysicalTechnical Specifications Chapter Installation and Setup Package ContentsSite Requirements and Prerequisites To set the jumpers Configuring RIC-E1Setting the Jumpers To install RIC-E1RIC-E1 Jumper Locations RIC-E1 Jumper Settings Closing the RIC-E1 Case Connecting the InterfacesConnecting the E1 Line Selecting the ImpedanceConnecting the DC Power Connecting the PowerConnecting the DTE Connecting the AC PowerInstallation and Setup Front Panel Indicators Chapter OperationDesignation Color Function Turning Off Operating InstructionsTurning On Operating RIC-E1Chapter Troubleshooting Diagnostics Performing Local Analog LoopbackActivating Local Analog Loopback To activate the local analog loopback from RIC-E1/R TroubleshootingRIC-E1 Troubleshooting Deactivating Local Analog LoopbackTechnical Support Technical Support ASM-MN-214 Card Cage Line ConnectorDTE Connector Chapter RIC-E1/R CardASM-MN-214 Rear Panel DC Supply Power SupplyPower Supply with Redundancy AC SupplyIR-ETH or IR-ETH RIC-E1/R Front PanelASM-MN-214 Front Panel Installing the RIC-E1/R Card Setting Internal Jumpers and SwitchesRIC-E1/R PCB Layout RIC-E1/R Jumper Settings To install the RIC-E1/R card in the ASM-MN-214 card cage Installing RIC-E1/R into the ASM-MN-214 Card CageRIC-E1/R Card V.35, X.21 and RS-530 Interface Connectors Appendix a Interface Connector WiringSignal Function 36, 37-Pin RS-530, 25-pin Circuit V.36 Interface ConnectorPin Function Line Interface ConnectorTable A-3. RJ-45 Line Interface Connector, Pin Assignment Signal Function 36, 37-pin RS-530, 25-pin Pin CircuitAppendix a Interface Connector Wiring Contents Appendix B IR-ETH Interface ModuleIntroduction Table B-1. RJ-45 Pinout IR-ETH OptionsStandalone RIC-E1 RIC-E1/R CardFigure B-3. RIC-E1/R with IR-ETH Installation and Operation Setting the DIP Switch LED IndicatorsTable B-2. DIP Switch Settings ACT Connecting the LANTable B-4. IR-ETH LED Indicators, RIC-E1/R LinkAppendix C IR-ETH/V Interface Module IR-ETH/V Options RIC-E1 Data 00, 01, 02, … For example, MDI in OFF position, MDI is enabledMbps full duplex, 285 ∝s ThroughputSection Name Description Possible Settings Factory Setting Setting the DIP SwitchesTable C-2. DIP SW1 Switch Settings Moved by the user Table C-3. DIP Switch SW2 SettingsTable C-4. IR-ETH/V LED Indicators Backpressure and Flow ControlColor Function Introduction Appendix D IR-IP Interface ModuleAppendix D IR-IP Interface Module Frame Relay RFC Connector 10BaseT Shielded RJ-45Standard Ieee 802.3/Ethernet Data Rate ProtocolsRIC-E1/ IP Table D-2. IR-IP LEDs Functions RIC-E1/R Card IR-IP LEDsIR-IP Controls Table D-1. IR-IP LEDs Functions Standalone RIC-E1Table D-4 RJ-45 Pinout Control Function Values Default SettingIR-IP Management Subsystem, General Table D-3. IR-IP ControlsDefault IP Communication Parameters Accessing the IR-IP Management SubsystemTo allow the IR-IP configuration Performing Preliminary ConfigurationRescue Configuration Outline of Preliminary ConfigurationIP Learning Mechanism Connecting the Telnet HostPreliminary Telnet Host Configuration Assigning the Router LAN Interface AddressTo view and edit the ARP table contents To configure the IP router LAN addressAssigning a LAN IP Address to a New IR-IP No ping replies from IR-IP Changing the LAN IP Address of a Configured IR-IPAfter RIC-E1 is turned on, the ERR indicator does not light What to Do IfGeneral Operating Procedures IR-IP Management UtilityStarting a Management Utility Quick Setup Menu To access the Quick Setup menuMenu Structure of Management Utility WAN IP Address Default GatewayLAN IP Address LAN IP MaskDhcp Relay Read Protocol from DIP SwitchesOperation with Default Gateway To configure the IR-IP as a Dhcp relayProtocol Management Access MenuTelnet Password To access the Management Access menuTo access the Device Identification menu Advanced Setup MenuTelnet Inactivity Timeout To access the Advanced Setup menuContact Person To access the Interface Parameters menuInterface Parameters Menu Device NameWAN Protocol Parameters Frame Relay Protocol Menu Protocol Field Compression Authentication ProtocolWAN Protocol Parameters PPP Protocol Header and Control Field CompressionMulticast IP Figure D-17. Multicast IP Menu Multicast ForwardingTo access the Device Control menu Device ControlStatic Groups New Software Download Menu Viewing Error Log ScreenResetting the LAN Interface Erasing ConfigurationResets Menu Resetting the DeviceView Menu Configuration and ConnectionTo access the View menu To access the Configuration and Connection screenARP Tables To access the ARP Tables screenDisplaying Statistics To access the Multicast Groups Table screenTo access the Statistics menu Multicast Groups Table ScreenTo access the Diagnostic Tools menu Diagnostic Tools Ping TerminalTo ping a host Using the Ping FunctionDesired positions, and then turn the RIC-E1 on again Erasing User’s ConfigurationTo erase the user’s configuration Erasing IR-IP SoftwareCase, it is recommended to turn RIC-E1 off and then back on Erasing Application SoftwareDownloading New Software To erase the application softwareAppendix D IR-IP Interface Module Rear Panel Appendix E IR-X.21B Interface ModuleSelecting the IR-X.21B Timing EXT Clock ModeINT/LBT Clock Mode IR-X.21BBuffer Appendix E IR-X.21B Interface Module IR-ETH Impedance, 2-4IndicatorsIndex IP-IRIR-IP LEDRequirements, 2-1RIC-E1/R Card Excellent Good Fair Poor Very Poor Customer Response FormError Report Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters