RAD Data comm RIC-E1 operation manual Technical Support

Page 31

RIC-E1Installation and Operation Manual

Chapter 4 Troubleshooting and Diagnostics

 

 

 

 

 

 

 

 

 

4.3 Technical Support

Technical support for this product can be obtained from the local distributor from whom it was purchased.

For further information, please contact the RAD distributor nearest you or one of RAD's offices worldwide.

Technical Support

4-3

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Image 31
Contents RIC-E1 Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters RAD Data Communications Inc RIC-E1Limited Warranty Please observe the following precautions General Safety InstructionsConnection of AC Mains General Safety PracticesConnection of DC Mains Isdn Ports Safety StatusElectromagnetic Compatibility EMC Canadian Emission Requirements Supplementary Information SafetyManufacturers Name Manufacturers Address Product NamesQuick Start Guide Installing RIC-E1Setting the Internal Jumpers Jumper Description Values Default SettingOperating RIC-E1 Connecting the CablesTo connect cables Contents List of Figures Versions Power SupplyChapter Introduction OverviewApplication Physical DescriptionTiming Reference Functional Block DiagramDiagnostics Functional DescriptionInternal oscillator Technical SpecificationsReceive, derived from the received signal Derived from three alternative sourcesEnvironment DiagnosticsPower PhysicalTechnical Specifications Package Contents Chapter Installation and SetupSite Requirements and Prerequisites To set the jumpers Configuring RIC-E1Setting the Jumpers To install RIC-E1RIC-E1 Jumper Locations RIC-E1 Jumper Settings Closing the RIC-E1 Case Connecting the InterfacesConnecting the E1 Line Selecting the ImpedanceConnecting the DC Power Connecting the PowerConnecting the DTE Connecting the AC PowerInstallation and Setup Chapter Operation Front Panel IndicatorsDesignation Color Function Turning Off Operating InstructionsTurning On Operating RIC-E1Performing Local Analog Loopback Chapter Troubleshooting DiagnosticsActivating Local Analog Loopback To activate the local analog loopback from RIC-E1/R TroubleshootingRIC-E1 Troubleshooting Deactivating Local Analog LoopbackTechnical Support Technical Support ASM-MN-214 Card Cage Line ConnectorDTE Connector Chapter RIC-E1/R CardASM-MN-214 Rear Panel DC Supply Power SupplyPower Supply with Redundancy AC SupplyIR-ETH or IR-ETH RIC-E1/R Front PanelASM-MN-214 Front Panel Setting Internal Jumpers and Switches Installing the RIC-E1/R CardRIC-E1/R PCB Layout RIC-E1/R Jumper Settings To install the RIC-E1/R card in the ASM-MN-214 card cage Installing RIC-E1/R into the ASM-MN-214 Card CageRIC-E1/R Card V.35, X.21 and RS-530 Interface Connectors Appendix a Interface Connector WiringSignal Function 36, 37-Pin RS-530, 25-pin Circuit V.36 Interface ConnectorPin Function Line Interface ConnectorTable A-3. RJ-45 Line Interface Connector, Pin Assignment Signal Function 36, 37-pin RS-530, 25-pin Pin CircuitAppendix a Interface Connector Wiring Appendix B IR-ETH Interface Module ContentsIntroduction Table B-1. RJ-45 Pinout IR-ETH OptionsStandalone RIC-E1 RIC-E1/R CardFigure B-3. RIC-E1/R with IR-ETH Installation and Operation LED Indicators Setting the DIP SwitchTable B-2. DIP Switch Settings ACT Connecting the LANTable B-4. IR-ETH LED Indicators, RIC-E1/R LinkAppendix C IR-ETH/V Interface Module IR-ETH/V Options RIC-E1 Data 00, 01, 02, … For example, MDI in OFF position, MDI is enabledMbps full duplex, 285 ∝s ThroughputSection Name Description Possible Settings Factory Setting Setting the DIP SwitchesTable C-2. DIP SW1 Switch Settings Moved by the user Table C-3. DIP Switch SW2 SettingsBackpressure and Flow Control Table C-4. IR-ETH/V LED IndicatorsColor Function Introduction Appendix D IR-IP Interface ModuleAppendix D IR-IP Interface Module Frame Relay RFC Connector 10BaseT Shielded RJ-45Standard Ieee 802.3/Ethernet Data Rate ProtocolsRIC-E1/ IP Table D-2. IR-IP LEDs Functions RIC-E1/R Card IR-IP LEDsIR-IP Controls Table D-1. IR-IP LEDs Functions Standalone RIC-E1Table D-4 RJ-45 Pinout Control Function Values Default SettingIR-IP Management Subsystem, General Table D-3. IR-IP ControlsDefault IP Communication Parameters Accessing the IR-IP Management SubsystemTo allow the IR-IP configuration Performing Preliminary ConfigurationRescue Configuration Outline of Preliminary ConfigurationIP Learning Mechanism Connecting the Telnet HostPreliminary Telnet Host Configuration Assigning the Router LAN Interface AddressTo configure the IP router LAN address To view and edit the ARP table contentsAssigning a LAN IP Address to a New IR-IP No ping replies from IR-IP Changing the LAN IP Address of a Configured IR-IPAfter RIC-E1 is turned on, the ERR indicator does not light What to Do IfIR-IP Management Utility General Operating ProceduresStarting a Management Utility To access the Quick Setup menu Quick Setup MenuMenu Structure of Management Utility WAN IP Address Default GatewayLAN IP Address LAN IP MaskDhcp Relay Read Protocol from DIP SwitchesOperation with Default Gateway To configure the IR-IP as a Dhcp relayProtocol Management Access MenuTelnet Password To access the Management Access menuTo access the Device Identification menu Advanced Setup MenuTelnet Inactivity Timeout To access the Advanced Setup menuContact Person To access the Interface Parameters menuInterface Parameters Menu Device NameWAN Protocol Parameters Frame Relay Protocol Menu Protocol Field Compression Authentication ProtocolWAN Protocol Parameters PPP Protocol Header and Control Field CompressionMulticast IP Figure D-17. Multicast IP Menu Multicast ForwardingDevice Control To access the Device Control menuStatic Groups New Software Download Menu Viewing Error Log ScreenResetting the LAN Interface Erasing ConfigurationResets Menu Resetting the DeviceView Menu Configuration and ConnectionTo access the View menu To access the Configuration and Connection screenARP Tables To access the ARP Tables screenDisplaying Statistics To access the Multicast Groups Table screenTo access the Statistics menu Multicast Groups Table ScreenTo access the Diagnostic Tools menu Diagnostic Tools Ping TerminalTo ping a host Using the Ping FunctionDesired positions, and then turn the RIC-E1 on again Erasing User’s ConfigurationTo erase the user’s configuration Erasing IR-IP SoftwareCase, it is recommended to turn RIC-E1 off and then back on Erasing Application SoftwareDownloading New Software To erase the application softwareAppendix D IR-IP Interface Module Rear Panel Appendix E IR-X.21B Interface ModuleSelecting the IR-X.21B Timing EXT Clock ModeIR-X.21B INT/LBT Clock ModeBuffer Appendix E IR-X.21B Interface Module IR-ETH Impedance, 2-4IndicatorsIndex IP-IRLED IR-IPRequirements, 2-1RIC-E1/R Card Excellent Good Fair Poor Very Poor Customer Response FormError Report Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters