RAD Data comm Chapter RIC-E1/R Card, ASM-MN-214 Card Cage, Line Connector, DTE Connector

Page 33

Chapter 5

RIC-E1/R Card

This chapter describes the RIC-E1/R card version, designed for installation in the ASM-MN-214 card cage. The chapter contains the following sections:

The ASM-MN-214 card cage

The RIC-E1/R card version

Power supply to RIC-E1/R card

Installing the RIC-E1/R card.

5.1 ASM-MN-214 Card Cage

The ASM-MN-214 card cage contains one or two power supplies and up to

14 plug-in cards. The card types can be RIC-E1/R or other RAD rack version modems/converters – any combination of up to 14 plug-in cards.

For each of the 14 cards, the rear panel (see Figure 5-1)contains a male connector for the terminal block and a DB-25 connector. A protection cover protects the terminal block connectors.

Line Connector

The line is to be attached to the rear panel terminal block connectors

(see Figure 5-1). It contains screws for connecting the transmit and receive pairs and ground, if present. When operating RIC-E1/R with unbalanced E1 interface, use a CIA/TB-BNC/214 adapter, which converts the terminal block connector into two coaxial BNC connectors (see Figure 5-1).

The ASM-MN-214 card cage is also available with BNC coaxial unbalanced or RJ-45 balanced line connectors.

DTE Connector

The 25-pin D-type female interface connector provides all interface signals for the digital interfaces. Units with X.21 or V.35 interface require an external mechanical adapter. Two optional interface attachments, CIA/X21/1 and CIA/V.35/1, can be ordered separately from RAD. CIA/X.21/1 converts one DB-25 connector to an X.21 15-pin connector. CIA/V.35/1 converts one DB-25 connector to a V.35 34-pin connector.

V.36 converter cards are supplied with a RAD adapter cable CBL-530/449F, which converts between the DB-25 connector and a V.36 37-pin connector.

ASM-MN-214 Card Cage

5-1

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Image 33
Contents RIC-E1 Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters RAD Data Communications Inc RIC-E1Limited Warranty Please observe the following precautions General Safety InstructionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Isdn Ports Safety StatusElectromagnetic Compatibility EMC Canadian Emission Requirements Manufacturers Name Manufacturers Address SafetyProduct Names Supplementary InformationSetting the Internal Jumpers Installing RIC-E1Jumper Description Values Default Setting Quick Start GuideConnecting the Cables Operating RIC-E1To connect cables Contents List of Figures Chapter Introduction Power SupplyOverview VersionsApplication Physical DescriptionDiagnostics Functional Block DiagramFunctional Description Timing ReferenceReceive, derived from the received signal Technical SpecificationsDerived from three alternative sources Internal oscillatorPower DiagnosticsPhysical EnvironmentTechnical Specifications Chapter Installation and Setup Package ContentsSite Requirements and Prerequisites Setting the Jumpers Configuring RIC-E1To install RIC-E1 To set the jumpersRIC-E1 Jumper Locations RIC-E1 Jumper Settings Connecting the E1 Line Connecting the InterfacesSelecting the Impedance Closing the RIC-E1 CaseConnecting the DTE Connecting the PowerConnecting the AC Power Connecting the DC PowerInstallation and Setup Front Panel Indicators Chapter OperationDesignation Color Function Turning On Operating InstructionsOperating RIC-E1 Turning OffChapter Troubleshooting Diagnostics Performing Local Analog LoopbackActivating Local Analog Loopback RIC-E1 Troubleshooting TroubleshootingDeactivating Local Analog Loopback To activate the local analog loopback from RIC-E1/RTechnical Support Technical Support DTE Connector Line ConnectorChapter RIC-E1/R Card ASM-MN-214 Card CageASM-MN-214 Rear Panel Power Supply with Redundancy Power SupplyAC Supply DC SupplyIR-ETH or IR-ETH RIC-E1/R Front PanelASM-MN-214 Front Panel Installing the RIC-E1/R Card Setting Internal Jumpers and SwitchesRIC-E1/R PCB Layout RIC-E1/R Jumper Settings To install the RIC-E1/R card in the ASM-MN-214 card cage Installing RIC-E1/R into the ASM-MN-214 Card CageRIC-E1/R Card V.35, X.21 and RS-530 Interface Connectors Appendix a Interface Connector WiringSignal Function 36, 37-Pin RS-530, 25-pin Circuit V.36 Interface ConnectorTable A-3. RJ-45 Line Interface Connector, Pin Assignment Line Interface ConnectorSignal Function 36, 37-pin RS-530, 25-pin Pin Circuit Pin FunctionAppendix a Interface Connector Wiring Contents Appendix B IR-ETH Interface ModuleIntroduction Standalone RIC-E1 IR-ETH OptionsRIC-E1/R Card Table B-1. RJ-45 PinoutFigure B-3. RIC-E1/R with IR-ETH Installation and Operation Setting the DIP Switch LED IndicatorsTable B-2. DIP Switch Settings Table B-4. IR-ETH LED Indicators, RIC-E1/R Connecting the LANLink ACTAppendix C IR-ETH/V Interface Module IR-ETH/V Options RIC-E1 Mbps full duplex, 285 ∝s For example, MDI in OFF position, MDI is enabledThroughput Data 00, 01, 02, …Table C-2. DIP SW1 Switch Settings Setting the DIP SwitchesMoved by the user Table C-3. DIP Switch SW2 Settings Section Name Description Possible Settings Factory SettingTable C-4. IR-ETH/V LED Indicators Backpressure and Flow ControlColor Function Introduction Appendix D IR-IP Interface ModuleAppendix D IR-IP Interface Module Standard Ieee 802.3/Ethernet Data Rate Connector 10BaseT Shielded RJ-45Protocols Frame Relay RFCRIC-E1/ IP IR-IP Controls IR-IP LEDsTable D-1. IR-IP LEDs Functions Standalone RIC-E1 Table D-2. IR-IP LEDs Functions RIC-E1/R CardIR-IP Management Subsystem, General Control Function Values Default SettingTable D-3. IR-IP Controls Table D-4 RJ-45 PinoutDefault IP Communication Parameters Accessing the IR-IP Management SubsystemRescue Configuration Performing Preliminary ConfigurationOutline of Preliminary Configuration To allow the IR-IP configurationPreliminary Telnet Host Configuration Connecting the Telnet HostAssigning the Router LAN Interface Address IP Learning MechanismTo view and edit the ARP table contents To configure the IP router LAN addressAssigning a LAN IP Address to a New IR-IP After RIC-E1 is turned on, the ERR indicator does not light Changing the LAN IP Address of a Configured IR-IPWhat to Do If No ping replies from IR-IPGeneral Operating Procedures IR-IP Management UtilityStarting a Management Utility Quick Setup Menu To access the Quick Setup menuMenu Structure of Management Utility LAN IP Address Default GatewayLAN IP Mask WAN IP AddressOperation with Default Gateway Read Protocol from DIP SwitchesTo configure the IR-IP as a Dhcp relay Dhcp RelayTelnet Password Management Access MenuTo access the Management Access menu ProtocolTelnet Inactivity Timeout Advanced Setup MenuTo access the Advanced Setup menu To access the Device Identification menuInterface Parameters Menu To access the Interface Parameters menuDevice Name Contact PersonWAN Protocol Parameters Frame Relay Protocol Menu WAN Protocol Parameters PPP Protocol Authentication ProtocolHeader and Control Field Compression Protocol Field CompressionMulticast IP Figure D-17. Multicast IP Menu Multicast ForwardingTo access the Device Control menu Device ControlStatic Groups New Software Download Menu Viewing Error Log ScreenResets Menu Erasing ConfigurationResetting the Device Resetting the LAN InterfaceTo access the View menu Configuration and ConnectionTo access the Configuration and Connection screen View MenuARP Tables To access the ARP Tables screenTo access the Statistics menu To access the Multicast Groups Table screenMulticast Groups Table Screen Displaying StatisticsTo access the Diagnostic Tools menu Diagnostic Tools Ping TerminalTo ping a host Using the Ping FunctionTo erase the user’s configuration Erasing User’s ConfigurationErasing IR-IP Software Desired positions, and then turn the RIC-E1 on againDownloading New Software Erasing Application SoftwareTo erase the application software Case, it is recommended to turn RIC-E1 off and then back onAppendix D IR-IP Interface Module Rear Panel Appendix E IR-X.21B Interface ModuleSelecting the IR-X.21B Timing EXT Clock ModeINT/LBT Clock Mode IR-X.21BBuffer Appendix E IR-X.21B Interface Module Index Impedance, 2-4IndicatorsIP-IR IR-ETHIR-IP LEDRequirements, 2-1RIC-E1/R Card Excellent Good Fair Poor Very Poor Customer Response FormError Report Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 International Headquarters