2SHUDWRUOperation &RQWUROV
The operator controls for the
F-60+ Operation and Maintenance Manual
6.UPPER ROLL HEAT ON/OFF – Turns the heater controller for the upper main roll on or off.
7.LOWER ROLL HEATER CONTROLLER– Provides a readout of the temperature of the lower roll and the
8.LOWER ROLL HEAT ON/OFF – Turns the heater controller for the lower main roll on or off.
9.COOLING FAN ON/OFF – Turns the cooling fan on or off.
| 100 |
|
| 90 |
|
| 80 |
|
| 70 |
|
1 | 60 | CAL 3200 |
50 |
| |
Roll | 40 |
|
Pressure | 30 |
|
Display | 20 |
|
| 10 |
|
CAL 3200
5
6
7
8
Upper Roll Heater Controller
Upper Roll Heat
ON/OFF
Lower Roll Heater Controller
Lower Roll Heat
ON/OFF
10. POWER ON/OFF INDICATOR – Indicates
when the main power is being applied to the
)RRWVZLWFKmachine. 2SHUDWLRQ
The footswitch can be used for feeding materials through the main rolls (forward mode). Material speed is controlled by the Control Panel Speed Adjustment
RUN/STOP/ | 2 |
|
|
|
|
|
|
| |
EYE RESET |
|
|
|
|
Motion Control | 3 |
|
|
|
|
|
|
| |
FORWARD/ |
|
|
|
|
REVERSE |
|
|
| 5 6 |
|
| 4 |
| 7 |
|
| 3 |
| 8 |
Speed | 4 | 2 | 2 | 9 |
|
|
| ||
Adjustment |
| 1 |
| 10 |
9 | Cooling Fan ON/OFF |
|
10
Power On/Off Indicator
knob, resulting in constant speed operation when the footswitch is pressed. The footswitch can also be used for feeding materials through the pull rolls (reverse mode). Material speed is controlled by the footswitch, which operates much like the accelerator on an auto- mobile.
Figure 3-4: Front Control Panel
1. | ROLL PRESSURE DISPLAY - Displays the per- |
| centage of force pushing the main laminating roll |
| down. |
2. | RUN/STOP/EYE RESET – Turns the drive sys- |
| tem on or off and resets the photoelectric eyes |
| when in automatic forward mode. The photoelec- |
| tric eyes do not function in reverse mode. |
3. | MOTION CONTROL FORWARD/REVERSE - |
| Controls the direction of the drive system, forward, |
CAUTION
When the footswitch is used the photoelectric eye guarding the main rolls is turned off. Release the footswitch to stop the machine rolls.
| reverse, or stop. |
4. | SPEED ADJUSTMENT – Adjusts the speed of |
| the machine from zero to the maximum as the con- |
| trol is turned clockwise. (Turtle is slow, rabbit is |
| fast.) |
5. | UPPER ROLL HEATER CONTROLLER – |
| Provides a readout of the temperature of the upper |
| roll and the |
☞NOTE
Feed
Material
Into Nip
Remove
Guard
| 0 | + | ™ | |
F |
|
| ||
|
|
|
-TECH PRO
Press Footswitch (variable speed)
The bottom roll heater controller must be turned on before the top roll heater controller will energize the top heater.
Figure 3-5: Using the Footswitch
© GBC |