Operating the Library
Setting and Viewing SCSI IDs
Interpreting SCSI Bus Status Indicator LEDs
Each SCSI bus has an LED to indicate the bus status.
Table | SCSI Status Indicators | |||
|
|
|
|
|
|
| Indication | Status | |
|
|
|
| |
| Steady green | Port active and OK. Internal | ||
|
|
| enabled. | |
|
|
|
| |
| Flashing green | Port active and OK. Internal | ||
|
|
| disabled. | |
|
|
|
| |
| No light | Port not active or not configured. | ||
|
|
|
| |
| Flashing red | Bus mismatch or loss of external termination power. | ||
|
|
|
| |
| Flashing yellow | Bus | ||
|
|
|
| |
| Viewing Current SCSI Address Settings | |||
|
|
| ||
| 1 2 → ADMIN * → SCSI IDs * → VIEW IDs * |
| ||
|
|
| ||
| To view the current SCSI address settings: | |||
| 1. | Verify that the drive status displays. If not, press CANCEL until it does. | ||
| 2. | Press NEXT until ADMIN * displays, then press ENTER. | ||
| 3. | Enter the | ||
|
| Menu Password” on page | ||
| 4. | Press NEXT until SCSI IDs * displays, then press ENTER. | ||
| 5. | SET IDS * displays. Press NEXT until VIEW IDS * displays, then press ENTER. | ||
| 6. | BUS # LIB ID # or BUS # DRV # ID * displays. (BUS # LIB ID # stands for | ||
|
| the current SCSI ID of the robotics controller. BUS # DRV # ID # is the current | ||
|
| SCSI ID setting for the displayed drive number and its associated BUS#.) | ||
| 7. | Press NEXT or PREV to scroll through the current address settings. | ||
| 8. | Press CANCEL until the next operation to perform displays, or until the drive | ||
|
| status (library “ready” state) displays. |