Operating the Library

 

 

 

Troubleshooting

 

 

 

 

 

 

Problem

 

What to do

 

 

 

 

 

 

 

DEVICE FAILED displays.

Make sure that only one SCSI device type (single-ended OR

 

 

Hardware Error #61 (External SCSI

 

differential) exists on the SCSI bus.

 

 

 

 

 

 

cables) is reported.

Verify that the library SCSI selector switch is set correctly

 

 

 

 

(either single-ended or differential).

 

 

 

• Verify that the mode switch termination is set correctly.

 

 

 

 

 

 

 

The library’s power failed while a

Press the power switch off and then on again. (See the

 

 

cartridge was in the drive and did not

 

caution note at the end of this table.)

 

 

return to the drive status indicators

• If the power-on test is unsuccessful, switch off the power.

 

 

 

Library

("ready" state) after the power came

 

 

Call a service representative for assistance.

 

 

 

 

back on.

 

 

 

 

 

 

 

 

 

 

 

 

No display messages appear.

Make sure the power cord is connected.

 

Operation

 

Power cycle the library. (See the caution note at the end of

 

 

• Make sure the power switch is on.

 

 

 

 

this table.)

 

 

 

• If there is still no display, call a service representative for

 

 

 

 

 

 

assistance.

 

 

 

 

 

 

 

3-39