IPmux-16 Installation and Operation Manual Chapter 1 Introduction
Technical Specifications 1-17

T1

Framing

Compliance
Framing
Signaling
ANSI T1.403
Passthrough, SF, ESF
CAS (bit robbing), CCS (transparent)

Local

Terminal

and

Control

Interface

Mode
Baud Rate
Connector
RS-232 over RJ-45 (adapter cable to DB-15 supplied)
DTE
9.6, 19.2, 38.4, 57.6, 115.2 kbps
DB-9

Dry

Contact

Alarm

Connector
Contacts
DB-9
30V 2A
Ethernet Modules
Compliance
Connector
Ports
Data Rate
Range
IEEE 802.3, 802.3u, Ethernet, 802.1 p&q
RJ-45, 8 pin
1
10 Mbps or 100 Mbps, full or half duplex
Up to 100m over UTP Category 5 cables
General System Indicators
General:
PS1 Green ON when main power supply is
OK
OFF when malfunction is
detected, power does not exist or
power is off.
PS2 Green ON when se condary power
supply is OK
OFF when secondary power
supply does not exist (no power
supply redundancy) or when
power is off
RDY Green ON when self-test is successfully
completed
OFF during self-test
BLINKS when self-test fails
ALM Red: ON when a Minor alarm is
detected
OFF when no alarms are
detected