1.4 Technical Specifications

E1 Modules

E1 Port

Ports

 

Compliance

 

Connector

 

Data Rate

 

Line Code

 

Line Impedance

 

Signal Levels

 

Jitter Performance

 

External Adapter

 

Cable

E1

Compliance

Framing

Framing

 

Signaling

Up to 16

ITU-T Rec. G.703, G.706, G.732, G.823

Balanced: RJ-45 8 pin

Unbalanced: TBNC 75(an external adapter cable from TBNC to BNC is required)

2.048 Mbps HDB3

Balanced: 120; Unbalanced: 75

Receive: 0 to –27 dB with LTU 0 to –10 dB without LTU

Transmit Balanced: ±3V ±10%

Transmit Unbalanced: ±2.37V ±10% ITU-T G.823 standard

TBNC to BNC required for unbalanced interfaces

G.704, G.706

Passthrough, CRC4 MF, CAS MF

CAS, CCS (transparent)

T1 Modules

T1 Port

Ports

 

Compliance

 

Connector

 

Data Rate

 

Line Code

 

Line Impedance

 

Signal Levels

Jitter Performance

Up to 16

ANSI T1.403, ITU-T Rec. G.703 RJ-45, 8 pin

1.544 Mbps B8ZS, B7ZS, AMI Balanced: 100

Receive: 0 to –27 dB

Transmit: 0 dB, –7.5 dB, –15 dB, –22.5 with CSU

±2.7V ± 10%, adjustable, measured in range 0 to 655 feet without CSU

AT&T TR-62411, G.824 standards