Chapter 3 Operation IPmux-16 Installation and Operation Manual
3-32 Configuring IPmux-16
To determine the 2 or 4 bit code applied to AB(D4) or ABCD (ESF) bits when
fault conditions occur:
Type B (Cond CAS (ABCD) pattern).
The ABCD conditioning pattern can be applied toward the IP path when loss
of signal, loss of frame or AIS detected at the T1 line. Conditioning pattern can
also be applied toward the T1 line when packet receive buffer overrun or
under run occur.
(This field will not appear if “unframed” is selected in the Channel Type field.)
Range: 1–F
Default value: 1
To determine the 2 or 4 bit code applied (during the first 2.5 seconds) to
AB(D4) or ABCD (ESF) bits (relevant in CAS mode only) when fault conditions
occur:
Type C (Cond. CAS first 2.5 sec pattern). This code will be inserted in the first
2.5 seconds and then the code specified in ‘Cond. CAS (ABCD) pattern’ will
be applied. ABCD conditioning pattern can be applied toward the IP path
when loss of signal, loss of frame or AIS detected at the T1 line. A conditioning
pattern can also be applied toward the T1 line when packet receive buffer
overrun or underrun occur. When configuring FF to this function, this
parameter will be ignored and the CAS pattern that will be applied in the first
2.5 seconds will be the same as defined in ‘ Cond. CAS (ABCD) pattern’.
This field will not appear if “unframed” is selected in the Line Type field or if
CAS Disable is selected.
Range: 0–F (ESF), 0–3(D4), FF
Default value: FF
Time Slots Configuration
Main Menu
2. Configuration
3. Time Slots
Configuration
To configure the time slots:
Type 3 (Time Slots Configuration) in the Configuration menu.
This configuration defines the bundles you want to send. Up to 31/24
bundles can be sent for each E1/T1 (see Chapter 1, Functional Description
for further details.