IPmux-16 Installation and Operation Manual Chapter 3 Operation
Configuring IPmux-16 3-15
To set the manager list parameters:
1. Enter 1 to set the manager IP address: range of 0.0.0.0. to 255.255.255.255.
2. Enter 3 to set the alarm trap: On or Off. Use the Spacebar to toggle between
these two settings. When set to On, the alarm trap informs the manager of the
occurrence of any alarm enabled in the Alarms Trap Mask screen. It informs
the manager of both entry and exit from an alarm state. When OFF, no alarm
trap will be sent regardless of the Mask defined in the Alarm Trap Mask screen.
3. Enter 4 to set the system trap: On or Off. Use the Spacebar to toggle between
these two settings. When set to On, the system trap informs the manager
whenever there is a change in the system power-supply status, heat alarm.
4. To ping the manager, press P.
5. To access additional manager-list parameters, press N to go to the next
manager-list window.
Default Gateway
Main menu
2. Configuration
1. General
Configuration
3. Management
Configuration
4. Default
Gateway
Default gateway defines the gateway to which management frames will be sent
(when the manager is not in the host subnet). When a next hop is not defined in
the connection parameters, the default gateway is used.
To configure the default gateway
1. Type 4 (Default Gateway) in the Management Configuration menu.
DEFAULT GATEWAY
1. Gateway IP 0.0.0.0
ESC. Exit
Select item from the menu.
Figure 3-16. Default Gateway Menu
2. Type 1 and then type in the IP address of the default gateway.