IPmux-16Installation and Operation Manual

Chapter 3 Operation

 

 

To set the manager list parameters:

1.Enter 1 to set the manager IP address: range of 0.0.0.0. to 255.255.255.255.

2.Enter 3 to set the alarm trap: On or Off. Use the Spacebar to toggle between these two settings. When set to On, the alarm trap informs the manager of the occurrence of any alarm enabled in the Alarms Trap Mask screen. It informs the manager of both entry and exit from an alarm state. When OFF, no alarm trap will be sent regardless of the Mask defined in the Alarm Trap Mask screen.

3.Enter 4 to set the system trap: On or Off. Use the Spacebar to toggle between these two settings. When set to On, the system trap informs the manager whenever there is a change in the system power-supply status, heat alarm.

4.To ping the manager, press P.

5.To access additional manager-list parameters, press N to go to the next manager-list window.

Main menu

2. Configuration

1.General Configuration

3.Management

Configuration

4.Default Gateway

Default Gateway

Default gateway defines the gateway to which management frames will be sent (when the manager is not in the host subnet). When a next hop is not defined in the connection parameters, the default gateway is used.

To configure the default gateway

1. Type 4 (Default Gateway) in the Management Configuration menu.

DEFAULT GATEWAY

1. Gateway IP

0.0.0.0

ESC. Exit

 

Select item from the menu.

Figure 3-16. Default Gateway Menu

2. Type 1 and then type in the IP address of the default gateway.

Configuring IPmux-16

3-15

Page 47
Image 47