Chapter 2

Installation

2.1 Introduction

IPmux-16 is delivered completely assembled for bench-top installation. The only mechanical installation procedure that may be necessary is optional installation in a 19-inch rack.

After installing the unit, configure the IPmux-16 using an ASCII terminal connected to the IPmux-16 control port. The IPmux-16 configuration procedures are described in Chapter 3 of this manual.

If problems are encountered, refer to Chapter 4 for test and diagnostics instructions.

No internal settings, adjustment, maintenance and repairs may be performed by either the operator or the user; such activities may be performed only by

skilled service personnel who are aware of the hazards involved.

Warning Always observe standard safety precautions during installation, operation, and maintenance of this product.

2.2 Site Requirements and Prerequisites

AC-powered IPmux-16 units should be installed within 1.5m (5 feet) of an easily-accessible grounded AC outlet capable of furnishing the required supply voltage, in the range of 100 to 240 VAC, 16A maximum.

DC-powered IPmux-16 units require a –48 VDC power source (positive pole grounded).

Caution The DC power source must be isolated from the mains supply by double or reinforced insulation.

Allow at least 90 cm (36 in) of frontal clearance for operator access. Allow at least 10 cm (4 in) clearance at the rear of the unit for cable connections. Make sure that the ventilation holes are not blocked.

Site Requirements and Prerequisites

2-1

Page 27
Image 27
RAD Data comm IPmux-16 operation manual Introduction, Site Requirements and Prerequisites