Chapter 3 Operation

IPmux-16Installation and Operation Manual

 

 

System Usage

The number of open TDM timeslots being passed over the Ethernet (and the TDM bytes per frame configuration) are calculated for purposes of monitoring system performance capabilities. Any open bundle uses up system resources (until 100%). Once the system usage reaches 100%, no new bundles can be opened. Deleting or disabling open bundles will reduce system usage and will enable new bundles to be opened (see Chapter 1, Throughput Limitations and CAC, for more information). Because cross-connected bundles are passed internally, they do not affect system usage.

Setting VLAN and IP Support

VLAN ID (2) and VLAN Priority (3) are configurable only if VLAN Tagging (1) is set to Yes.

 

 

 

VLAN & IP SUPPORT

1.

VLAN Tagging

Yes

2.

VLAN

ID

3000

3.

VLAN

Priority

2

4.

IP ToS

200

ESC. Exit

Select item from the menu.

Figure 3-33. System Configuration Menu

Main Menu

2.Configuration

5.VLAN & IP Support

1.VLAN Tagging

VLAN Tagging

For an explanation of VLAN tagging see Chapter 1.

To set VLAN Tagging:

Type 1 (VLAN Tagging) in the VLAN & IP Support menu.

Use the <Spacebar> on your keyboard to toggle between Yes and No. If you choose Yes, set options 4 and 5 on the System Configuration Menu.

To set the VLAN ID:

Type 2 and enter the desired value (0-4095). Default value: 0.

To set the VLAN Priority:

Type 3 and enter the desired value (0-7). Default value: 0.

3-36 Configuring IPmux-16

Page 68
Image 68