Chapter 3 Operation IPmux-16 Installation and Operation Manual
3-36 Configuring IPmux-16

System Usage

The number of open TDM timeslots being passed over the Ethernet (and the TDM
bytes per frame configuration) are calculated for purposes of monitoring system
performance capabilities. Any open bundle uses up system resources (until 100%).
Once the system usage reaches 100%, no new bundles can be opened. Deleting
or disabling open bundles will reduce system usage and will enable new bundles
to be opened (see Chapter 1, Throughput Limitations and CAC, for more
information). Because cross-connected bundles are passed internally, they do not
affect system usage.
Setting VLAN and IP Support
VLAN & IP SUPPORT
1. VLAN Tagging Yes
2. VLAN ID 3000
3. VLAN Priority 2
4. IP ToS 200
ESC. Exit
Select item from the menu.
Figure 3-33. System Configuration Menu

VLAN Tagging

Main Menu
2. Configuration
5. VLAN & IP
Support
1. VLAN Tagging
For an explanation of VLAN tagging see Chapter 1.
To set VLAN Tagging:
Type 1 (VLAN Tagging) in the VLAN & IP Support menu.
Use the <Spacebar> on your keyboard to toggle between Yes and No.
If you choose Yes, set options 4 and 5 on the System Configuration Menu.
To set the VLAN ID:
Type 2 and enter the desired value (0-4095).
Default value: 0.
To set the VLAN Priority:
Type 3 and enter the desired value (0-7).
Default value: 0.
VLAN ID (2) and
VLAN Priority (3) are
configurable only if
VLAN Tagging (1) is
set to Yes.