Chapter 3 OperationIPmux-16Installation and Operation Manual

Table 3-1. IPmux-16 System Indicators and Switches

No

Module

Name

Type

Function

 

 

 

 

 

1

System

RDY

LED

On: Device OK

 

 

 

 

OFF: Self-test in progress

 

 

 

 

Blinking: Malfunction detected

 

 

 

 

 

2

System

PS1/PS2

LED

On: Unit powered

 

 

 

 

Off: Unit not powered

 

 

 

 

 

3

System

ALM

LED

Red: Alarm

 

 

 

 

Off: No alarm

 

 

 

 

 

4

Ethernet

LINK

LED

Off: Link not active

 

 

 

 

On: Line OK

 

 

 

 

 

5

Ethernet

ACT

LED

Off: No activity

 

 

 

 

On: Frame being transferred on line

 

 

 

 

 

6

Ethernet

100M

LED

Off: 10 MHz

 

 

 

 

On: 100 MHz

 

 

 

 

 

7

Ethernet

FDX

LED

Off: Half duplex

 

 

 

 

On: Full duplex

 

 

 

 

 

8

E1

SYNC

LED

On: Port synchronized (no alarm)

 

 

 

 

Off: Unframed - Signal loss or AIS

 

 

 

 

detected

 

 

 

 

Framed - Signal loss, loss of frame or

 

 

 

 

AIS detected

 

 

 

 

Blinking: RDI detected (remote alarm)

 

 

 

 

 

9

Rear panel

PS1/PS2

Switch

Turns IPmux-16 power on and off

 

 

 

 

 

3.3 Operating Instructions

Turning IPmux-16 On – Without Control Terminal

IPmux-16 power switches are located on the back panel, as shown in Figure 3-2.

To power up IPmux-16 without a terminal:

Switch the PS1 power supply switch, located on the rear panel, to ON. IPmux-16 can be optionally equipped with a second power supply (PS2). If present, switch PS2 to ON.

After power-up, check the unit LED indicators, located on the right side of the front panel, and the module indicators for proper operation (see Figure 3-1, Figure 3-2, and Table 3-1).

3-2 Operating Instructions

Page 34
Image 34
RAD Data comm Operating Instructions, Turning IPmux-16 On Without Control Terminal, Module Name Type Function