Chapter 1 Introduction

IPmux-16Installation and Operation Manual

 

 

Power

Physical

Environment Humidity

Ethernet Port:

LINK

OFF when line is not active

 

ON when line is OK

ACT

OFF when no activity

 

ON when a frame is being transmitted or

 

received on the line

FDX

OFF when half duplex

 

ON when full duplex

100M

OFF when 10 MHz

 

ON when 100 MHz

E1/T1 Port:

 

SYNC

ON when the port is synchronized (no alarm)

 

OFF when signal loss, LOF or AIS is detected

 

(local alarm)

 

BLINKS when RDI is detected (remote alarm)

Note: All LEDs are green and ON after power-up.

1 or 2 power supplies

40W, 100 to 240 VAC, 50/60 Hz –36 to –72 VDC (–48 VDC nominal)

Height 6.6 cm / 2.55 in (1.5U) Width 43.2 cm / 19 in Depth 35 cm / 13.78 in Weight 4.0 kg / 8.8 lb

Temperature: 0 to 45°C / 32 to 110°F Up to 90%, non-condensing

1-18 Technical Specifications

Page 26
Image 26
RAD Data comm IPmux-16 operation manual Power Physical