134COTS Servers

IBM x306m BIOS settings

The BIOS settings on the IBM x306m server shipped through Nortel are correct. These settings can be viewed at Table 8 "IBM x306m default BIOS settings" (page 134).

Table 8

IBM x306m default BIOS settings

BIOS value

Default setting

 

 

Devices and I/O port - serial port A

Enabled

 

 

Devices and I/O port - baud rate

9600 baud

 

 

Devices and I/O port - console type

PC ANSI

 

 

Devices and I/O port - flow control

Off

 

 

Devices and I/O port - continue C.R. after POST

On

 

 

Devices and I/O port - type of connector

9-pin serial female

 

 

Start options - legacy USB support

Disabled

 

 

The IBM x306m server default BIOS settings can be changed by a BIOS reset or other maintenance activity. To return the BIOS settings to the appropriate values, see “Changing the BIOS settings on an IBM x306m server” (page 134) for instructions.

For information about how to enable or disable the BIOS password on the IBM x306m server see “Setting the IBM x306m server BIOS password” (page 136).

Changing the BIOS settings on an IBM x306m server

Step Action

1Press the Power switch to boot the server.

The server boots and the Press F1 for Configuration/Setup message appears on the maintenance terminal.

Note: If the server is already up and running, power the server off and on or press the reset button to reboot and receive the Press F1 for Configuration/Setup message.

2Press F1 to invoke the IBM x306m server Configuration/Setup Utility.

The Configuration/Setup Utility menu screen appears.

Nortel Communication Server 1000

Linux Platform Base and Applications Installation and Commissioning

NN43001-315 02.09

29 October 2008

Copyright © 2007–2008 Nortel Networks

Page 134
Image 134
Nortel Networks NN43001-315 manual IBM x306m default Bios settings Bios value Default setting