128COTS Servers
A BIOS Serial Console Port configuration screen appears. This screen presents you with four options:
•1 Auto
•2 Disabled
•3 COM 1
•4 COM 2
5Navigate to the COM 1 option and press Enter.
This configures the COM 1 port as the serial port for communicating with the connected maintenance terminal.
The BIOS Serial Console & EMS configuration menu screen reappears.
6Press ESC to exit the BIOS Serial Console & EMS configuration menu screen.
The RBSU menu screen reappears.
7Press ESC to exit the
Changing the baud rate on an HP DL320 G4 Signaling Server
ATTENTION
The HP DL320 G4 server shipped through Nortel has a default Baud rate of 9600 b/ps and does not require a reset. Use this procedure only if you want to use another Baud rate, or to correct the Baud rate after it is reset due to an error.
Step Action
1Press Power to boot the server.
The server boots and the HP DL320 G4 boot screen appears.