Bunn S/N SNG0033000 & UP manual BUNN-O-MATIC Commercial Product Warranty

Page 2

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY

Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:

1)All equipment other than as specified below: 2 years parts and 1 year labor.

2)Electronic circuit and/or control boards: parts and labor for 3 years.

3)Compressors on refrigeration equipment: 5 years parts and 1 year labor.

4)Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.

These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.

If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.

THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.

In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.

BrewWISE, BUNN Gourmet Ice, BUNN Pour-O-Matic, BUNN, Bunn-OMatic, Bunn-O-Matic, BUNNlink, BUNNserve, BUNN Espress, DBC, Dr. Brew, Dual, EasyClear, EasyGard, Easy Pour, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, IMIX, Infusion Series, Legendary for Quality, The Mark of Quality in Beverage Equipment Worldwide, My Café, PowerLogic, Safety-Fresh, Single, Smart Funnel, Smart Hopper, Soft Heat, SplashGard, System III, ThermoFresh, 392, AXIOM, Bever- age Profit Calculator, Beverage Bar Creator, BrewLOGIC, BrewMETER, BrewWIZARD, BUNNSERVE, BUNNsource, Coffee At Its Best, Cool Froth, Digital Brewer Control, Intellisteam, Nothing Brews Like a BUNN, Pouring Profits, Pulse Wave, Quality Beverage Equipment Worldwide, Scale-Pro, Signature Series, Silver Series, Smart Heat, SmartWAVE, Tea At Its Best, The Horizontal Red Line, Titan, Ultra, are either trademarks or registered trademarks of Bunn-O-Matic Corporation.

Page 2

35879.1 011108

 

Image 2
Contents Single TF DBC Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices 37881.0002 Volt ac single phase Hz modelsElectrical HOOK-UP Electrical Requirements Models without power cord 230 volt ac Single phase, 60 Hz modelsPlumbing HOOK-UP CE RequirementsPlumbing Requirements ON/OFF Switch Enable Brew Main ON/OFF SwitchBatch Selector Switches Brew SwitchInitial Setup Coffee BrewingCleaning Glossary Programming Switches ProgrammingProgramming Switch DRIP-OUT Times Program Functions LevelRecipes Returns to a LevelContinues to D Continues to Program Flow DiagramReturn to a Programming the Brewer Units Setting Units of Measure Procedure for modifying units of measureThis function allows the operator to set Brew Procedure for Setting the RecipeSET NEW Recipe Refer to SET Pulse Brew for description SET NEW RecipesSizes DONE? Procedure to program the coffee name Card Contains Recipe forReview RECIPES? Noyes Next Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesProcedure for reviewing recipes To exit, press Next until the display reads ThatBrew OZ Setting or Adjusting Brew VOL- Umes ScreenBypass Review RecipesSET Pulse Brew Modifying pulse brew Range 1st on time off to 4 minutesNO-NAME Modifyshownext SET Pulse BrewSET Pulse Brew Easy Pulse Setup DONE? SET Pulse Brew Enter TimesTIMES? SET Preinfusion Batches DONE?Setup Complete Assign Recipe ? Enable ADS?Assign Recipes Screen Spray OZ/M SET TempSET Ready Calibrate Spray .. Press Brew to Start Bypass OZ/MCalibrate Flow Start Procedures to calibrate the bypass flow rateCalibrate Flow Brew Counters Procedure to set funnel detectProcedures to view/reset the brew counters Funnel Detect optionalProcedure to test components outputs Service ToolsTesting individual components outputs Brew ValveNothing Pressed FrequencyFactory Defaults Procedure to set factory defaultsScreen Displayed TroubleshootingTroubleshooting Procedures Possible CauseTemperature Press ON/OFF to terminate the cycleTank Heater failure ON/OFF switch was pressed after the brew cycle was startedPress ON/OFF to terminate the brew cycle Triac FailureWater shut off to brewer Temperature Sensor ProbeWires shorted to housing, or to Broken or not making connectionBrew Valve Switch test procedures Equipment will not operate No power or incorrect voltageBrew switch Switch test procedures Data plate within +/- 10%With power removed from brewer Holding it in open state Troubleshooting Problem Possible CauseOverflow Protection Switch When this condition occurs, See above or boilingLimit Thermostat Heating Time TOO LongTroubleshooting Problem Improper water pressure Inconsistent beverage level StrainerServer Pointing towards the brewer 90 psi 138 and 620 kPaLevel in server Consistently high or low beverage Brew Volume adjustmentWater temperature For each brew cycleBrewer is making unusual noises Troubleshooting Problem Possible Cause Weak beverageRemove and clean lime off tank heaters Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC