Bunn S/N SNG0033000 & UP manual Table of Contents

Page 3

TABLE OF CONTENTS

 

User Notices

4

Electrical

5

Plumbing Requirements

7

Operating Controls

8

Initial Setup

9

Coffee Brewing

9

Cleaning

10

Glossary

11

PROGRAMMING

12

Programming Switches

12

Programming the Brewer

13

PROGRAM FUNCTIONS (LEVEL 1) Brew Lockout

13

PROGRAM FUNCTIONS (LEVEL 2)

14

PROGRAM FUNCTIONS (FLOW)

15

Set Units (Setting units of measure)

18

Set New Recipe (using a Smart Funnel and G92T DBC or MHG Grinder)

19

Set Brew Volumes

19

Set By-Pass Percentages

20

Set Pulse Brew Times

20

Set Drip Times

20

Set New Recipe (using a Recipe Card)

18

Set New Recipe (no Smart Funnel nor G9-2T DBC Grinder)

19

Review Recipes/Modify Recipes/Set up No Name Coffee

20

Set Brew Volumes

24

Set Bypass Percentages

25

Set Pulse Brew Times

26

Easy Pulse

28

Enter Times

29

Set Preinfusion Times

30

Set Drip Times

31

Assign Recipes

32

Enable Ads

32

Set Temp (Brewing Temperature)

33

Set Ready (Ready Temperature)

33

Refill (Adjust Sensitivity)

33

Spray Oz/M (Read sprayhead flow rate)

34

Bypass Oz/M (Read bypass flow rate)

34

Calibrate Flow

34

Calibrate Sprayhead Flow

34

Calibrate Bypass Flow

35

Brew Counters (View/Reset)

36

Funnel Detect

36

Service Tools

37

Test Outputs (Components)

37

Test Switches

38

Test Frequency

38

Factory Defaults (Reset)

39

Troubleshooting

40

Schematic (Wiring Diagram)

51

Page 3

35879.1 071405

 

Image 3
Contents Phone 217 529-6601 FAX 217 Single TF DBCBUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices Volt ac single phase Hz models Electrical HOOK-UP37881.0002 230 volt ac Single phase, 60 Hz models Electrical Requirements Models without power cordCE Requirements Plumbing RequirementsPlumbing HOOK-UP Brew Switch Main ON/OFF SwitchBatch Selector Switches ON/OFF Switch Enable BrewCoffee Brewing Initial SetupCleaning Glossary Programming Programming SwitchesProgramming Switch Program Functions Level RecipesDRIP-OUT Times Level Continues to DReturns to a Program Flow Diagram Return to aContinues to Programming the Brewer Procedure for modifying units of measure Units Setting Units of MeasureProcedure for Setting the Recipe SET NEW RecipeThis function allows the operator to set Brew SET NEW Recipes Sizes DONE?Refer to SET Pulse Brew for description Card Contains Recipe for Procedure to program the coffee nameReview RECIPES? Noyes To exit, press Next until the display reads That Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesProcedure for reviewing recipes NextScreen Brew OZ Setting or Adjusting Brew VOL- UmesReview Recipes BypassModifying pulse brew Range 1st on time off to 4 minutes SET Pulse BrewSET Pulse Brew NO-NAME ModifyshownextSET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? Batches DONE? SET PreinfusionSetup Complete Enable ADS? Assign RecipesAssign Recipe ? SET Temp SET ReadyScreen Spray OZ/M Bypass OZ/M Calibrate FlowCalibrate Spray .. Press Brew to Start Procedures to calibrate the bypass flow rate Calibrate FlowStart Funnel Detect optional Procedure to set funnel detectProcedures to view/reset the brew counters Brew CountersBrew Valve Service ToolsTesting individual components outputs Procedure to test components outputsFrequency Nothing PressedProcedure to set factory defaults Factory DefaultsPossible Cause TroubleshootingTroubleshooting Procedures Screen DisplayedPress ON/OFF to terminate the cycle TemperatureTriac Failure ON/OFF switch was pressed after the brew cycle was startedPress ON/OFF to terminate the brew cycle Tank Heater failureBroken or not making connection Temperature Sensor ProbeWires shorted to housing, or to Water shut off to brewerData plate within +/- 10% Equipment will not operate No power or incorrect voltageBrew switch Switch test procedures Brew Valve Switch test proceduresSee above or boiling Troubleshooting Problem Possible CauseOverflow Protection Switch When this condition occurs, With power removed from brewer Holding it in open stateHeating Time TOO Long Limit ThermostatTroubleshooting Problem 90 psi 138 and 620 kPa Inconsistent beverage level StrainerServer Pointing towards the brewer Improper water pressureFor each brew cycle Consistently high or low beverage Brew Volume adjustmentWater temperature Level in serverPlumbing lines Water Supply Tank Heaters Troubleshooting Problem Possible Cause Weak beverageRemove and clean lime off tank heaters Brewer is making unusual noisesSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC