Bunn S/N SNG0033000 & UP manual Nothing Pressed, Frequency

Page 38

PROGRAMMING THE BREWER (cont.)

SERVICE TOOLS (cont.)

14.Press OFF to retract the funnel lock.

15.Press NEXT to advance to the next component to be tested.

16.To test REFILL VALVE, press ON. If the refill valve is functional, the sound of the valve operating will be heard.

17.Press OFF to end testing of refill valve.

18.Press NEXT to advance to the next component to be tested.

19.To test TANK HEATER, connect a voltmeter across the tank heater to check for voltage.

20.Press ON. The correct voltage should be present at the heater terminals.

21.Press OFF to end testing of the tank heater.

NOTE: The tank heater will automatically turn off if left on too long.

22.After testing the tank heater, press NEXT to advance to the next test.

23.The HEATER CONTACTOR is used only on certain models. Check the machine schematic to see if the contactor is present. Connect a voltmeter across the tank heater and press ON to check that cor- rect voltage is present. Press OFF and confirm the voltage is zero.

24.Press NEXT to return to TEST OUTPUTS.

25.To exit SERVICE TOOLS, press and release the ON/OFF switch located on the front switch panel. This will return to the MAIN SCREEN.

Procedure to test switches:

This function allows the operator to test the opera- tion of the individual switches on the front panel.

1.Place brew funnel into rails on the brewer.

2.Place a server beneath the brew funnel.

3.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads

SERVICE TOOLS.

4.Press YES to run tests on various components and outputs within the brewer. (Pressing NO will exit this function and advance to the next function screen.)

5.The display should read TEST OUTPUTS.

6.In TEST OUTPUTS screen, press NO. This advances

to TEST SWITCHES.

7.Pressing NO in this screen will advance to the next function. Press YES in the TEST SWITCHES screen to test the switches. The display will read

NOTHING PRESSED.

8.From this screen, press any of the switches on the front of the brewer. While the switch is pressed, the display shows the name of that switch. If the name does not appear, or if it remains after the switch has been released, the switch is defective. Each switch can be tested in this manner.

9.After all switches have been tested, press the up- per right hidden switch located on the front switch panel. This will exit TEST SWITCHES and return to the MAIN SCREEN.

Procedures to test coil frequency:

1.Place brew funnel into rails of the brewer.

2.Place a server beneath the brew funnel.

3.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads

SERVICE TOOLS.

4.Pressing NO will exit this function and advance to the next function screen. Press YES to run tests on various components and outputs within the brewer.

5.The display should read TEST OUTPUTS.

6.In TEST OUTPUTS screen, press NO. Continue to press and release NO until the display reads TEST

FREQUENCY.

7.Press and release YES. The display will show the frequency of the sensor coil circuits. This is for diagnostic service use when troubleshooting this circuit.

8.After the coils have been tested, press and release the ON/OFF switch located on the front switch panel. This will exit the TEST FREQUENCY function and return to the MAIN SCREEN.

NOTE: If the operator wishes to test more than one function in the SERVICE TOOLS section (outputs, switches, servers, or coil frequency), it is not necessary to exit the program. Use the flow chart for SERVICE TOOLS to navigate to a particular function.

Page 38

35879.1 071405

 

Image 38
Contents Single TF DBC Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices 37881.0002 Volt ac single phase Hz modelsElectrical HOOK-UP Electrical Requirements Models without power cord 230 volt ac Single phase, 60 Hz modelsPlumbing HOOK-UP CE RequirementsPlumbing Requirements ON/OFF Switch Enable Brew Main ON/OFF SwitchBatch Selector Switches Brew SwitchInitial Setup Coffee BrewingCleaning Glossary Programming Switches ProgrammingProgramming Switch DRIP-OUT Times Program Functions LevelRecipes Returns to a LevelContinues to D Continues to Program Flow DiagramReturn to a Programming the Brewer Units Setting Units of Measure Procedure for modifying units of measureThis function allows the operator to set Brew Procedure for Setting the RecipeSET NEW Recipe Refer to SET Pulse Brew for description SET NEW RecipesSizes DONE? Procedure to program the coffee name Card Contains Recipe forReview RECIPES? Noyes Next Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesProcedure for reviewing recipes To exit, press Next until the display reads ThatBrew OZ Setting or Adjusting Brew VOL- Umes ScreenBypass Review RecipesSET Pulse Brew Modifying pulse brew Range 1st on time off to 4 minutesNO-NAME Modifyshownext SET Pulse BrewSET Pulse Brew Easy Pulse Setup DONE? SET Pulse Brew Enter TimesTIMES? SET Preinfusion Batches DONE?Setup Complete Assign Recipe ? Enable ADS?Assign Recipes Screen Spray OZ/M SET TempSET Ready Calibrate Spray .. Press Brew to Start Bypass OZ/MCalibrate Flow Start Procedures to calibrate the bypass flow rateCalibrate Flow Brew Counters Procedure to set funnel detectProcedures to view/reset the brew counters Funnel Detect optionalProcedure to test components outputs Service ToolsTesting individual components outputs Brew ValveNothing Pressed FrequencyFactory Defaults Procedure to set factory defaultsScreen Displayed TroubleshootingTroubleshooting Procedures Possible CauseTemperature Press ON/OFF to terminate the cycleTank Heater failure ON/OFF switch was pressed after the brew cycle was startedPress ON/OFF to terminate the brew cycle Triac FailureWater shut off to brewer Temperature Sensor ProbeWires shorted to housing, or to Broken or not making connectionBrew Valve Switch test procedures Equipment will not operate No power or incorrect voltageBrew switch Switch test procedures Data plate within +/- 10%With power removed from brewer Holding it in open state Troubleshooting Problem Possible CauseOverflow Protection Switch When this condition occurs, See above or boilingLimit Thermostat Heating Time TOO LongTroubleshooting Problem Improper water pressure Inconsistent beverage level StrainerServer Pointing towards the brewer 90 psi 138 and 620 kPaLevel in server Consistently high or low beverage Brew Volume adjustmentWater temperature For each brew cycleBrewer is making unusual noises Troubleshooting Problem Possible Cause Weak beverageRemove and clean lime off tank heaters Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC