Bunn S/N SNG0033000 & UP manual Card Contains Recipe for, Procedure to program the coffee name

Page 21

PROGRAMMING THE BREWER (cont.)

SET NEW RECIPE

Using a RECIPE CARD to load coffee names and brew settings into the Brewer with Smart Funnel:

The G9-2T DBC or MHG's memory contains certain coffee names. If the operator uses a coffee name that is not already stored in the grinder's memory, a RECIPE CARD can be obtained from the factory. The RECIPE CARD would include all the information needed to set up that particular coffee name. The information from the RECIPE CARD is loaded into the grinder's memory, then into the brewer's memory by holding the chip area up to the equipment's sensing coil. This information can include the coffee name, BREW VOLUMES, BYPASS PERCENTAGES, PULSE BREW TIMES and DRIP-OUT TIMES for that particular coffee NAME. These can all be loaded in seconds.

Contact Bunn-O-Matic Corporation for the avail- ability of RECIPE CARDS.

NOTE: Instructions to program the brewer and grinder are printed on the RECIPE CARD, along with the coffee name that is being programmed.

Procedure to program the coffee name:

1.Remove the funnels (if present) from the left and right funnel rails.

2.Position the RECIPE CARD vertically, so that the top end of the CHIP is beneath the left side funnel sensing coil.

3.After a short pause the display will read CARD CON- TAINS RECIPE FOR then will change to (COFFEE NAME) SHOW QUIT SAVE. All brewing parameters for that coffee name are now transferred from the CARD to the brewer.

4.To show (view) this information, press and release SHOW. The display will scroll through all of the brew settings for all three batch sizes. The display will then return to CARD CONTAINS RECIPE FOR then will change to (COFFEE NAME) SHOW QUIT SAVE.

5.If all brew settings are correct, press SAVE. The display will read (COFFEE NAME) SETUP COM- PLETE. All brew settings for that name are now stored in the brewer's memory.

6.If the brewing information is not correct, or it is desired to exit the setup before the settings are loaded into the brewer's memory, press QUIT. The display will read (COFFEE NAME) NOT SAVED. The display will then return to the MAIN SCREEN.

READY TO BREW

WATER TEMP: 200º

POSITION CARD UNDER THE

LEFT SIDE SENSOR COIL

CARD CONTAINS

RECIPE FOR

(COFFEE NAME) SHOW QUIT SAVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCROLLS THROUGH ALL

 

(COFFEE NAME)

 

OF THE BREW SETTINGS

 

SETUP COMPLETE

FOR THE THREE BATCH

 

SIZES FOR THAT COFFEE

 

 

 

 

NAME

 

 

 

 

 

 

 

 

 

 

 

(COFFEE NAME)

 

 

NOT SAVED

P2300

Page 21

35879.1 071405

 

Image 21
Contents Phone 217 529-6601 FAX 217 Single TF DBCBUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices Volt ac single phase Hz models Electrical HOOK-UP37881.0002 230 volt ac Single phase, 60 Hz models Electrical Requirements Models without power cordCE Requirements Plumbing RequirementsPlumbing HOOK-UP Batch Selector Switches Main ON/OFF SwitchON/OFF Switch Enable Brew Brew SwitchCoffee Brewing Initial SetupCleaning Glossary Programming Programming SwitchesProgramming Switch Program Functions Level RecipesDRIP-OUT Times Level Continues to DReturns to a Program Flow Diagram Return to aContinues to Programming the Brewer Procedure for modifying units of measure Units Setting Units of MeasureProcedure for Setting the Recipe SET NEW RecipeThis function allows the operator to set Brew SET NEW Recipes Sizes DONE?Refer to SET Pulse Brew for description Card Contains Recipe for Procedure to program the coffee nameReview RECIPES? Noyes Procedure for reviewing recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesNext To exit, press Next until the display reads ThatScreen Brew OZ Setting or Adjusting Brew VOL- UmesReview Recipes BypassModifying pulse brew Range 1st on time off to 4 minutes SET Pulse BrewSET Pulse Brew NO-NAME ModifyshownextSET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? Batches DONE? SET PreinfusionSetup Complete Enable ADS? Assign RecipesAssign Recipe ? SET Temp SET ReadyScreen Spray OZ/M Bypass OZ/M Calibrate FlowCalibrate Spray .. Press Brew to Start Procedures to calibrate the bypass flow rate Calibrate FlowStart Procedures to view/reset the brew counters Procedure to set funnel detectBrew Counters Funnel Detect optionalTesting individual components outputs Service ToolsProcedure to test components outputs Brew ValveFrequency Nothing PressedProcedure to set factory defaults Factory DefaultsTroubleshooting Procedures TroubleshootingScreen Displayed Possible CausePress ON/OFF to terminate the cycle TemperaturePress ON/OFF to terminate the brew cycle ON/OFF switch was pressed after the brew cycle was startedTank Heater failure Triac FailureWires shorted to housing, or to Temperature Sensor ProbeWater shut off to brewer Broken or not making connectionBrew switch Switch test procedures Equipment will not operate No power or incorrect voltageBrew Valve Switch test procedures Data plate within +/- 10%Overflow Protection Switch When this condition occurs, Troubleshooting Problem Possible CauseWith power removed from brewer Holding it in open state See above or boilingHeating Time TOO Long Limit ThermostatTroubleshooting Problem Server Pointing towards the brewer Inconsistent beverage level StrainerImproper water pressure 90 psi 138 and 620 kPaWater temperature Consistently high or low beverage Brew Volume adjustmentLevel in server For each brew cycleRemove and clean lime off tank heaters Troubleshooting Problem Possible Cause Weak beverageBrewer is making unusual noises Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC