INITIAL SETUP

CAUTION – The brewer must be disconnected from the power source throughout the initial setup, except when specified in the instructions.

1.Insert an empty funnel into the funnel rails of the brew station.

2.Place an empty server under the funnel.

3.Connect the brewer to the power source. Water will begin flowing into the tank and stop when the tank is filled to its capacity. Display will show PLEASE WAIT...TANK FILLING until tank is filled with water.

4.Wait approximately 20 mins for the water in the tank to heat to the proper temperature on 120V/208V ma- chines. (Wait approximately 45 mins on 120V machines). Display will show READY TO BREW...WATER TEMP: XXX˚ when tank is at operating temperature.

5.Place a small vessel beneath the faucet and open the faucet handle. Release it when you hear the tank refill- ing.

6.Water volumes have been preset at the factory. Refer to adjustments for the Set Brew Volumes section of this manual should the volume need to be increased or decreased.

7.The brewer is now ready for use in accordance with the coffee brewing instructions.

COFFEE BREWING

1.Insert a BUNN filter into the Smart Funnel.

2.If a grinder is not used to obtain the coffee grounds, pour the proper amount of fresh coffee grounds into the funnel and level by gently shaking. Slide the funnel into the funnel rails and select batch size. Proceed to step 5.

3.If a G9-2T DBC or MHG grinder is used with a compatible Smart Funnel, select the desired batch size on the grinder. Grind the selected amount of fresh coffee into funnel and level grounds by gently shaking. It is not necessary to select a size on the brewer.

4.Slide the funnel into the funnel rails. The brewer will read the size ground through the chip in the funnel handle and will automatically select the correct size to brew.

5.Place an empty server under the funnel.

6The ENABLE BREW switch must be ON (indicator lit). Momentarily press and release the BREW switch. If the brewer has the funnel lock option and if it is activated, once a brew cycle has been started the funnel is locked in place. There may be certain situations in which the brew cycle will not begin when BREW switch is pressed:

a)ENABLE BREW must be ON.

b)BREW TEMPERATURE TOO LOW - wait until heated or cancel BREW LOCKOUT option.

c)FUNNEL NOT IN PLACE (or using a standard brew funnel) - cancel FUNNEL DETECT.

d)CHECK FUNNEL - remove funnel, empty previously brewed grounds and grind a new batch into the fun-

nel.

7.If none of the above messages are displayed, the display will read NOW BREWING and the time remaining in the brew cycle.

8.Following the BREW will be a countdown DRIPPING time which shows the time remaining until the funnel lock will release. Discard the grounds and filter only after visible dripping stops.

Page 9

35879.1 062107

 

Image 9
Contents Phone 217 529-6601 FAX 217 Single TF DBCBUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices Volt ac single phase Hz models Electrical HOOK-UP37881.0002 230 volt ac Single phase, 60 Hz models Electrical Requirements Models without power cordCE Requirements Plumbing RequirementsPlumbing HOOK-UP Batch Selector Switches Main ON/OFF SwitchON/OFF Switch Enable Brew Brew SwitchCoffee Brewing Initial SetupCleaning Glossary Programming Programming SwitchesProgramming Switch Program Functions Level RecipesDRIP-OUT Times Level Continues to DReturns to a Program Flow Diagram Return to aContinues to Programming the Brewer Procedure for modifying units of measure Units Setting Units of MeasureProcedure for Setting the Recipe SET NEW RecipeThis function allows the operator to set Brew SET NEW Recipes Sizes DONE?Refer to SET Pulse Brew for description Card Contains Recipe for Procedure to program the coffee nameReview RECIPES? Noyes Procedure for reviewing recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesNext To exit, press Next until the display reads ThatScreen Brew OZ Setting or Adjusting Brew VOL- UmesReview Recipes BypassModifying pulse brew Range 1st on time off to 4 minutes SET Pulse BrewSET Pulse Brew NO-NAME ModifyshownextSET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? Batches DONE? SET PreinfusionSetup Complete Enable ADS? Assign RecipesAssign Recipe ? SET Temp SET ReadyScreen Spray OZ/M Bypass OZ/M Calibrate FlowCalibrate Spray .. Press Brew to Start Procedures to calibrate the bypass flow rate Calibrate FlowStart Procedures to view/reset the brew counters Procedure to set funnel detectBrew Counters Funnel Detect optionalTesting individual components outputs Service ToolsProcedure to test components outputs Brew ValveFrequency Nothing PressedProcedure to set factory defaults Factory DefaultsTroubleshooting Procedures TroubleshootingScreen Displayed Possible CausePress ON/OFF to terminate the cycle TemperaturePress ON/OFF to terminate the brew cycle ON/OFF switch was pressed after the brew cycle was startedTank Heater failure Triac FailureWires shorted to housing, or to Temperature Sensor ProbeWater shut off to brewer Broken or not making connectionBrew switch Switch test procedures Equipment will not operate No power or incorrect voltageBrew Valve Switch test procedures Data plate within +/- 10%Overflow Protection Switch When this condition occurs, Troubleshooting Problem Possible CauseWith power removed from brewer Holding it in open state See above or boilingHeating Time TOO Long Limit ThermostatTroubleshooting Problem Server Pointing towards the brewer Inconsistent beverage level StrainerImproper water pressure 90 psi 138 and 620 kPaWater temperature Consistently high or low beverage Brew Volume adjustmentLevel in server For each brew cycleRemove and clean lime off tank heaters Troubleshooting Problem Possible Cause Weak beverageBrewer is making unusual noises Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC