TROUBLESHOOTING (cont.) |
|
Problem | Possible Cause |
Weak beverage (cont.) | 6. Incorrect Recipe |
Brewer is making unusual noises. | 1. Solenoid (Inlet) |
2. Plumbing lines
3. Water Supply
4. Tank Heaters.
Troubleshooting Procedures
Consider adjusting bypass percent- age, preinfusion, or pulse brew. Contact
The nut on back of the solenoid must be tight or it will vibrate during operation
Plumbing lines should not be resting on the counter top.
(A)The brewer must be connected to a cold water line.
(B)Water pressure to the brewer must not be higher than 90 psi (620 kPa). Install a regulator if necessary to lower the working pressure to ap- proximately 50 psi (345 kPa).
Remove and clean lime off tank heaters.
Page 50 | 35879.1 071405 |
|