Bunn S/N SNG0033000 & UP manual SET Temp, SET Ready, Screen Spray OZ/M

Page 33

PROGRAMMING THE BREWER (cont.)

SET TEMP (cont,)

SET TEMP: XXX° (-) DONE (+)

P2721

Procedure to set brew temperature:

1.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads

SET TEMP.

2.To adjust the brew temperature, press (-)to de- crease or (+) to increase the brew temperature.

3.When finished, press and release DONE to save the new setting, exit the SET TEMP function and advance to the next function screen, SET READY. Another alternative is to press the ON/OFF switch located on the front switch panel to exit the SET TEMP function and return to the MAIN SCREEN.

SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C) This function allows the operator to set the mini- mum temperature allowable to start a brew cycle. The range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) of the SET TEMP. The water must be at the SET READY temperature or higher for the display to indicate READY TO BREW. If brew lockout is enabled, the brewing pro-

cess will not start below this READY temperature.

NOTE: The upper limit is the water temperature control setting minus 2˚F (-1.7°C).

SET READY: XXX° (-) DONE (+)

P2721

Procedure to set ready temperature:

1.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads

SET READY.

2.To adjust the ready temperature, press the (-)switch to decrease, or (+) to increase the ready temperature.

3.When finished, press and release DONE to save the new setting, exit the SET READY function and ad- vance to the next function screen, REFILL. Another alternative is to press the ON/OFF switch located on the front switch panel to exit the SET READY function and return to the MAIN SCREEN.

REFILL - Range: 20 to 230

This function allows the operator to adjust the sensitivity of the refill circuit. This is mainly a trouble- shooting feature. Water in different geographical loca- tions can have different conductivities. By adjusting the sensitivity of the refill circuit, this will allow the brewer to operate under various water conditions.

XXXREFILL -> XXX (-) DONE (+)

P2721

Procedure to set the sensitivity threshold of the refill circuit:

NOTE: Make sure the water in the tank is touching the refill probe.

1.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads REFILL and shows a number on both sides of the word.

2.To adjust the threshold setting, press (-)to de- crease, or (+) to increase the setting.

NOTE: Always make sure that the number on the right is larger than the number on the left when water is in contact with the refill probe in the tank.

3.When finished, press and release DONE. This saves the new setting and advances to the next function screen, SPRAY OZ/M. Another alternative is to press the ON/OFF switch located on the front switch panel to exit REFILL and return to the MAIN

SCREEN.

SPRAY OZ/M

This function allows the operator to view or to enter the actual flow rate coming out of the sprayhead. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing. The unit of measure is ounces per minute. (Oz/M)

Page 33

35879.1 071405

 

Image 33
Contents Phone 217 529-6601 FAX 217 Single TF DBCBUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices Volt ac single phase Hz models Electrical HOOK-UP37881.0002 230 volt ac Single phase, 60 Hz models Electrical Requirements Models without power cordCE Requirements Plumbing RequirementsPlumbing HOOK-UP Batch Selector Switches Main ON/OFF SwitchON/OFF Switch Enable Brew Brew SwitchCoffee Brewing Initial SetupCleaning Glossary Programming Programming SwitchesProgramming Switch Program Functions Level RecipesDRIP-OUT Times Level Continues to DReturns to a Program Flow Diagram Return to aContinues to Programming the Brewer Procedure for modifying units of measure Units Setting Units of MeasureProcedure for Setting the Recipe SET NEW RecipeThis function allows the operator to set Brew SET NEW Recipes Sizes DONE?Refer to SET Pulse Brew for description Card Contains Recipe for Procedure to program the coffee nameReview RECIPES? Noyes Procedure for reviewing recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesNext To exit, press Next until the display reads ThatScreen Brew OZ Setting or Adjusting Brew VOL- UmesReview Recipes BypassModifying pulse brew Range 1st on time off to 4 minutes SET Pulse BrewSET Pulse Brew NO-NAME ModifyshownextSET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? Batches DONE? SET PreinfusionSetup Complete Enable ADS? Assign RecipesAssign Recipe ? SET Temp SET ReadyScreen Spray OZ/M Bypass OZ/M Calibrate FlowCalibrate Spray .. Press Brew to Start Procedures to calibrate the bypass flow rate Calibrate FlowStart Procedures to view/reset the brew counters Procedure to set funnel detectBrew Counters Funnel Detect optionalTesting individual components outputs Service ToolsProcedure to test components outputs Brew ValveFrequency Nothing PressedProcedure to set factory defaults Factory DefaultsTroubleshooting Procedures TroubleshootingScreen Displayed Possible CausePress ON/OFF to terminate the cycle TemperaturePress ON/OFF to terminate the brew cycle ON/OFF switch was pressed after the brew cycle was startedTank Heater failure Triac FailureWires shorted to housing, or to Temperature Sensor ProbeWater shut off to brewer Broken or not making connectionBrew switch Switch test procedures Equipment will not operate No power or incorrect voltageBrew Valve Switch test procedures Data plate within +/- 10%Overflow Protection Switch When this condition occurs, Troubleshooting Problem Possible CauseWith power removed from brewer Holding it in open state See above or boilingHeating Time TOO Long Limit ThermostatTroubleshooting Problem Server Pointing towards the brewer Inconsistent beverage level StrainerImproper water pressure 90 psi 138 and 620 kPaWater temperature Consistently high or low beverage Brew Volume adjustmentLevel in server For each brew cycleRemove and clean lime off tank heaters Troubleshooting Problem Possible Cause Weak beverageBrewer is making unusual noises Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC