Bunn S/N SNG0033000 & UP manual User Notices

Page 4

USER NOTICES

The notices on this brewer should be kept in good condition. Replace unreadable or damaged labels.

00658.0000

03408.0004

03409.0004

20201.5600

MAIN ON/OFF

SWITCH 00824.0000

00831.0000

This equipment must be installed to comply with the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Adminis- tration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /SanitationCode.

00656.0000

37881.0000

39803.0000

00824.0001

27508.0000

Page 4

35879.1 011108

 

Image 4
Contents Single TF DBC Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices Electrical HOOK-UP Volt ac single phase Hz models37881.0002 Electrical Requirements Models without power cord 230 volt ac Single phase, 60 Hz modelsPlumbing Requirements CE RequirementsPlumbing HOOK-UP Main ON/OFF Switch Batch Selector SwitchesON/OFF Switch Enable Brew Brew SwitchInitial Setup Coffee BrewingCleaning Glossary Programming Switches ProgrammingProgramming Switch Recipes Program Functions LevelDRIP-OUT Times Continues to D LevelReturns to a Return to a Program Flow DiagramContinues to Programming the Brewer Units Setting Units of Measure Procedure for modifying units of measureSET NEW Recipe Procedure for Setting the RecipeThis function allows the operator to set Brew Sizes DONE? SET NEW RecipesRefer to SET Pulse Brew for description Procedure to program the coffee name Card Contains Recipe forReview RECIPES? Noyes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee Names Procedure for reviewing recipesNext To exit, press Next until the display reads ThatBrew OZ Setting or Adjusting Brew VOL- Umes ScreenBypass Review RecipesSET Pulse Brew Modifying pulse brew Range 1st on time off to 4 minutesNO-NAME Modifyshownext SET Pulse BrewSET Pulse Brew Easy Pulse Setup TIMES? SET Pulse Brew Enter TimesDONE? SET Preinfusion Batches DONE?Setup Complete Assign Recipes Enable ADS?Assign Recipe ? SET Ready SET TempScreen Spray OZ/M Calibrate Flow Bypass OZ/MCalibrate Spray .. Press Brew to Start Calibrate Flow Procedures to calibrate the bypass flow rateStart Procedure to set funnel detect Procedures to view/reset the brew countersBrew Counters Funnel Detect optionalService Tools Testing individual components outputsProcedure to test components outputs Brew ValveNothing Pressed FrequencyFactory Defaults Procedure to set factory defaultsTroubleshooting Troubleshooting ProceduresScreen Displayed Possible CauseTemperature Press ON/OFF to terminate the cycleON/OFF switch was pressed after the brew cycle was started Press ON/OFF to terminate the brew cycleTank Heater failure Triac FailureTemperature Sensor Probe Wires shorted to housing, or toWater shut off to brewer Broken or not making connectionEquipment will not operate No power or incorrect voltage Brew switch Switch test proceduresBrew Valve Switch test procedures Data plate within +/- 10%Troubleshooting Problem Possible Cause Overflow Protection Switch When this condition occurs,With power removed from brewer Holding it in open state See above or boilingLimit Thermostat Heating Time TOO LongTroubleshooting Problem Inconsistent beverage level Strainer Server Pointing towards the brewerImproper water pressure 90 psi 138 and 620 kPaConsistently high or low beverage Brew Volume adjustment Water temperatureLevel in server For each brew cycleTroubleshooting Problem Possible Cause Weak beverage Remove and clean lime off tank heatersBrewer is making unusual noises Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC