Bunn S/N SNG0033000 & UP manual Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee Names, Next

Page 23

PROGRAMMING THE BREWER (cont.)

REVIEW RECIPES/MODIFY RECIPES/SET UP NO NAME COFFEE NAMES:

This function has three parts. It allows the operator to view the brew settings for the various coffee names programmed into the brewer.

It also allows the operator to modify (change) any of the BREW VOLUMES, BYPASS PERCENTAGES, PULSE BREW TIMES and DRIP-OUT TIMES for a particular coffee name programmed into the brewer.

Finally, this function is used to set up the NO NAME coffee BREW VOLUMES, BYPASS PERCENTAGES, PULSE BREW TIMES and DRIP-OUT TIMES.

Procedure for reviewing recipes:

1.Press and hold the ® pad until the display reads 1. Press and hold the upper right hidden switch ® until the display reads UNITS. Release the switch, then press and release switch until the display reads REVIEW RECIPES.

2.Press YES to proceed. The display should now read NO-NAME,along with MODIFY, SHOW and

NEXT.

3.Press and release SHOW. The screen will scroll through all the brew settings for that particular coffee name. When finished, the display will return to the coffee name just viewed.

4.To see settings again, press SHOW. To advance to the next coffee name, press NEXT.

5.To exit, press NEXT until the display reads THAT

WAS THE LAST RECIPE.

6.After 5 seconds, the display will return to the REVIEW RECIPES screen. Press and release NO to advance to the next function screen, or press and release the ON/OFF switch located on the front switch panel to exit the programming mode and return to the MAIN SCREEN.

REVIEW RECIPES?

NOYES

EXIT TO

NEXT FUNCTION

SCREEN

NO-NAME

MODIFYSHOWNEXT

SCROLLS THROUGH ALL

BREW SETTINGS FOR

NO-NAME COFFEE

P2442

ADVANCES TO ALL OTHER

COFFEE NAMES PROGRAMMED

IN THE BREWER'S MEMORY

(COFFEE NAME)

MODIFYSHOWNEXT

SCROLLS THROUGH ALL

BREW SETTINGS FOR ANY

OTHER OFFEE NAMES

STORED IN BREWER'S MEMORY

WHEN THE LAST COFFEE NAME

IN THE BREWER'S MEMORY IS

DISPLAYED, PRESSING NEXT

WILL EXIT AND THE DISPLAY

WILL THEN READ:

THAT WAS THE

LAST RECIPE

Page 23

35879.1 071405

 

Image 23
Contents Phone 217 529-6601 FAX 217 Single TF DBCBUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices 37881.0002 Volt ac single phase Hz modelsElectrical HOOK-UP 230 volt ac Single phase, 60 Hz models Electrical Requirements Models without power cordPlumbing HOOK-UP CE RequirementsPlumbing Requirements Brew Switch Main ON/OFF SwitchBatch Selector Switches ON/OFF Switch Enable BrewCoffee Brewing Initial SetupCleaning Glossary Programming Programming SwitchesProgramming Switch DRIP-OUT Times Program Functions LevelRecipes Returns to a LevelContinues to D Continues to Program Flow DiagramReturn to a Programming the Brewer Procedure for modifying units of measure Units Setting Units of MeasureThis function allows the operator to set Brew Procedure for Setting the RecipeSET NEW Recipe Refer to SET Pulse Brew for description SET NEW RecipesSizes DONE? Card Contains Recipe for Procedure to program the coffee nameReview RECIPES? Noyes To exit, press Next until the display reads That Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesProcedure for reviewing recipes NextScreen Brew OZ Setting or Adjusting Brew VOL- UmesReview Recipes BypassModifying pulse brew Range 1st on time off to 4 minutes SET Pulse BrewSET Pulse Brew NO-NAME ModifyshownextSET Pulse Brew Easy Pulse Setup DONE? SET Pulse Brew Enter TimesTIMES? Batches DONE? SET PreinfusionSetup Complete Assign Recipe ? Enable ADS?Assign Recipes Screen Spray OZ/M SET TempSET Ready Calibrate Spray .. Press Brew to Start Bypass OZ/MCalibrate Flow Start Procedures to calibrate the bypass flow rateCalibrate Flow Funnel Detect optional Procedure to set funnel detectProcedures to view/reset the brew counters Brew CountersBrew Valve Service ToolsTesting individual components outputs Procedure to test components outputsFrequency Nothing PressedProcedure to set factory defaults Factory DefaultsPossible Cause TroubleshootingTroubleshooting Procedures Screen DisplayedPress ON/OFF to terminate the cycle TemperatureTriac Failure ON/OFF switch was pressed after the brew cycle was startedPress ON/OFF to terminate the brew cycle Tank Heater failureBroken or not making connection Temperature Sensor ProbeWires shorted to housing, or to Water shut off to brewerData plate within +/- 10% Equipment will not operate No power or incorrect voltageBrew switch Switch test procedures Brew Valve Switch test proceduresSee above or boiling Troubleshooting Problem Possible CauseOverflow Protection Switch When this condition occurs, With power removed from brewer Holding it in open stateHeating Time TOO Long Limit ThermostatTroubleshooting Problem 90 psi 138 and 620 kPa Inconsistent beverage level StrainerServer Pointing towards the brewer Improper water pressureFor each brew cycle Consistently high or low beverage Brew Volume adjustmentWater temperature Level in serverPlumbing lines Water Supply Tank Heaters Troubleshooting Problem Possible Cause Weak beverageRemove and clean lime off tank heaters Brewer is making unusual noisesSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC