Bunn S/N SNG0033000 & UP manual SET Pulse Brew Enter Times, Times?, Done?

Page 29

PROGRAMMING THE BREWER (cont.)

SET PULSE BREW - ENTER TIMES

NOTE: The procedure to enter the PULSE BREW function must be performed prior to following the steps listed below.

1.Press and release YES. The display should now read EASY PULSE SETUP.

2.Press and release NO. The display will read ENTER

TIMES?

3.Press YES to proceed. The display should now read 1st ON TIME X:XX.

4.Using (-)and (+) set the amount of time the flow of water into the funnel will be on.

5.When finished, press DONE. The display will now read OFF TIMES: X:XX.

6.Using (-)and (+) set the amount of time the flow of water into the funnel will be off.

7.When finished, press DONE. The display will now read LAST ON: X.XX

8.Using (-)and (+) set the amount of time the water will be on to complete the brew.

9.When finished, press DONE. The display will show the three times just entered for that batch size. After a 5 second delay, the display will read 3 BATCHES

DONE?

10.If other batch sizes need to be modified, press

NO.

12.Press a different batch size and repeat steps 3 through 7. Repeat until all the desired batch sizes are set.

13.When finished press YES in 3 BATCHES DONE?. The display will then read DRIP TIME.

14.Press and release the ON/OFF switch located on the front switch panel to exit the SET PULSE BREW function and return to the MAIN SCREEN.

NOTE: Pressing the upper right hidden button before reaching the final setting screen exits the setup and retains the old values.

SET PULSE BREW?

NOYES

EASY PULSE SETUP

NOYES

EXIT TO

NEXT FUNCTION

SCREEN

ENTER TIMES?

NOYES

1st ON TIME X:XX

(-) DONE (+)

OFF TIMES: X:XX

(-) DONE (+)

LAST ON: X.XX

(-) DONE (+)

1st OFF LAST XX.X XX.X XX.X

5 SEC. DELAY

3 BATCHES DONE?

NO YES

EXIT TO

NEXT FUNCTION

SCREEN

P3265

Page 29

35879.1 071405

 

Image 29
Contents Phone 217 529-6601 FAX 217 Single TF DBCBUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices 37881.0002 Volt ac single phase Hz modelsElectrical HOOK-UP 230 volt ac Single phase, 60 Hz models Electrical Requirements Models without power cordPlumbing HOOK-UP CE RequirementsPlumbing Requirements Batch Selector Switches Main ON/OFF SwitchON/OFF Switch Enable Brew Brew SwitchCoffee Brewing Initial SetupCleaning Glossary Programming Programming SwitchesProgramming Switch DRIP-OUT Times Program Functions LevelRecipes Returns to a LevelContinues to D Continues to Program Flow DiagramReturn to a Programming the Brewer Procedure for modifying units of measure Units Setting Units of MeasureThis function allows the operator to set Brew Procedure for Setting the RecipeSET NEW Recipe Refer to SET Pulse Brew for description SET NEW RecipesSizes DONE? Card Contains Recipe for Procedure to program the coffee nameReview RECIPES? Noyes Procedure for reviewing recipes Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesNext To exit, press Next until the display reads ThatScreen Brew OZ Setting or Adjusting Brew VOL- UmesReview Recipes BypassModifying pulse brew Range 1st on time off to 4 minutes SET Pulse BrewSET Pulse Brew NO-NAME ModifyshownextSET Pulse Brew Easy Pulse Setup DONE? SET Pulse Brew Enter TimesTIMES? Batches DONE? SET PreinfusionSetup Complete Assign Recipe ? Enable ADS?Assign Recipes Screen Spray OZ/M SET TempSET Ready Calibrate Spray .. Press Brew to Start Bypass OZ/MCalibrate Flow Start Procedures to calibrate the bypass flow rateCalibrate Flow Procedures to view/reset the brew counters Procedure to set funnel detectBrew Counters Funnel Detect optionalTesting individual components outputs Service ToolsProcedure to test components outputs Brew ValveFrequency Nothing PressedProcedure to set factory defaults Factory DefaultsTroubleshooting Procedures TroubleshootingScreen Displayed Possible CausePress ON/OFF to terminate the cycle TemperaturePress ON/OFF to terminate the brew cycle ON/OFF switch was pressed after the brew cycle was startedTank Heater failure Triac FailureWires shorted to housing, or to Temperature Sensor ProbeWater shut off to brewer Broken or not making connectionBrew switch Switch test procedures Equipment will not operate No power or incorrect voltageBrew Valve Switch test procedures Data plate within +/- 10%Overflow Protection Switch When this condition occurs, Troubleshooting Problem Possible CauseWith power removed from brewer Holding it in open state See above or boilingHeating Time TOO Long Limit ThermostatTroubleshooting Problem Server Pointing towards the brewer Inconsistent beverage level StrainerImproper water pressure 90 psi 138 and 620 kPaWater temperature Consistently high or low beverage Brew Volume adjustmentLevel in server For each brew cycleRemove and clean lime off tank heaters Troubleshooting Problem Possible Cause Weak beverageBrewer is making unusual noises Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC