TROUBLESHOOTING (cont.)

 

 

Problem

Possible Cause

Troubleshooting Procedures

Water flows into tank continuously with power applied to brewer.

1.Refill Probe or Sensitivity Set- ting

Check the sensitivity setting. Refer to the Refill function. If the left three digit number is less than the right number, the machine “thinks” it is full and the refill valve should be off. If the left number is larger than the right, then the refill valve will automatically be turned on to fill the tank. The right number is the threshold setting and can be adjusted to compensate for extreme water conditions: very pure, low conductance water requires a higher setting, while high mineral content, high conductance water requires a lower setting. Note that the left number changes from a high value when water is NOT touching the refill probe to a low value when water IS touching the probe. For best opera- tion, the right number should be set to a value midway between these low and high numbers. Before changing the setting, confirm that the refill probe is free of scale buildup and the connection to it is secure.

2.

Electronic Control Board

Water will not heat or display shows 1.

Limit Thermostat

HEATING TIME TOO LONG

 

CAUTION - Do not eliminate or bypass limit thermostat. Use only replacement part #23717.0001.

2. Tank Heaters

Substitute a control board known to be in good working order.

Remove power from the brewer. Press reset button on limit ther- mostat. Then check for continuity through it.

Remove power from the brewer. Check for continuity through the tank heaters.

Page 46

35879.1 071405

 

Image 46
Contents Single TF DBC Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Table of Contents User Notices Electrical HOOK-UP Volt ac single phase Hz models37881.0002 Electrical Requirements Models without power cord 230 volt ac Single phase, 60 Hz modelsPlumbing Requirements CE RequirementsPlumbing HOOK-UP ON/OFF Switch Enable Brew Main ON/OFF SwitchBatch Selector Switches Brew SwitchInitial Setup Coffee BrewingCleaning Glossary Programming Switches ProgrammingProgramming Switch Recipes Program Functions LevelDRIP-OUT Times Continues to D LevelReturns to a Return to a Program Flow DiagramContinues to Programming the Brewer Units Setting Units of Measure Procedure for modifying units of measureSET NEW Recipe Procedure for Setting the RecipeThis function allows the operator to set Brew Sizes DONE? SET NEW RecipesRefer to SET Pulse Brew for description Procedure to program the coffee name Card Contains Recipe forReview RECIPES? Noyes Next Review RECIPES/MODIFY RECIPES/SET UP no Name Coffee NamesProcedure for reviewing recipes To exit, press Next until the display reads ThatBrew OZ Setting or Adjusting Brew VOL- Umes ScreenBypass Review RecipesSET Pulse Brew Modifying pulse brew Range 1st on time off to 4 minutesNO-NAME Modifyshownext SET Pulse BrewSET Pulse Brew Easy Pulse Setup TIMES? SET Pulse Brew Enter TimesDONE? SET Preinfusion Batches DONE?Setup Complete Assign Recipes Enable ADS?Assign Recipe ? SET Ready SET TempScreen Spray OZ/M Calibrate Flow Bypass OZ/MCalibrate Spray .. Press Brew to Start Calibrate Flow Procedures to calibrate the bypass flow rateStart Brew Counters Procedure to set funnel detectProcedures to view/reset the brew counters Funnel Detect optionalProcedure to test components outputs Service ToolsTesting individual components outputs Brew ValveNothing Pressed FrequencyFactory Defaults Procedure to set factory defaultsScreen Displayed TroubleshootingTroubleshooting Procedures Possible CauseTemperature Press ON/OFF to terminate the cycleTank Heater failure ON/OFF switch was pressed after the brew cycle was startedPress ON/OFF to terminate the brew cycle Triac FailureWater shut off to brewer Temperature Sensor ProbeWires shorted to housing, or to Broken or not making connectionBrew Valve Switch test procedures Equipment will not operate No power or incorrect voltageBrew switch Switch test procedures Data plate within +/- 10%With power removed from brewer Holding it in open state Troubleshooting Problem Possible CauseOverflow Protection Switch When this condition occurs, See above or boilingLimit Thermostat Heating Time TOO LongTroubleshooting Problem Improper water pressure Inconsistent beverage level StrainerServer Pointing towards the brewer 90 psi 138 and 620 kPaLevel in server Consistently high or low beverage Brew Volume adjustmentWater temperature For each brew cycleBrewer is making unusual noises Troubleshooting Problem Possible Cause Weak beverageRemove and clean lime off tank heaters Plumbing lines Water Supply Tank HeatersSchematic Wiring Diagram Single TF DBC Schematic Wiring Diagram Wire Single Phase Schematic Wiring Diagram Single TF DBC