AMCC 9590SE-4ME manual Cx/ux flush, Cx/ux set autoverify=onoff, Cx/ux set cache=onoff quiet

Page 67

Unit Object Commands

/cx/ux flush

This command allows you to flush the write cache on the specified unit /ux associated with controller /cx. Note that this command does not apply to spare unit types.

/cx/ux set autoverify=onoff

This feature only applies to 9000 series controllers.

This command allows you to turn on and off the autoverify operation on a specified unit /cx/ux during allocated schedule windows.

You can use the show verify command to display the existing schedule windows. By default, autoverify is off.

Auto-verify allows the controller to run the verify function once every 24 hours. If verify schedule windows are set up and enabled, then the controller will ony start an automatic verify task during the schedule time slots. If the verify takes longer than the schedule window, the verify process will be paused and restarted during the next verify schedule window. For additional information, see “Setting Up a Verify Schedule” on page 46.

/cx/ux set cache=onoff [quiet]

This command allows you to turn on or off the write cache for a specified unit /cx/ux. This feature is supported on both 7000/8000 and 9000 models.

By default, cache is on.

Write cache includes the disk drive cache and controller cache. Note that for some configuration types, there is only disk drive cache and no controller cache (for example, JBOD).

The following table shows the supported RAID types for caching as a function of controller model and logical unit type. N/A (Not Applicable) refers to cases where the given logical unit type is not supported on a particular controller model.

Table 8: Supported RAID Types for Caching

Model

R0

R1

R5

R10

Single

Spare

 

 

 

 

 

 

 

7K/8K

Yes

Yes

Yes

Yes

N/A

No

 

 

 

 

 

 

 

9K

Yes

Yes

Yes

Yes

Yes

No

 

 

 

 

 

 

 

The quiet attribute turns off interactive mode.

www.3ware.com

61

Image 67
Contents 3ware Command Line InterfaceCopyright Table of Contents Page Cx/ux set autoverify=onoff Return Code About this CLI Guide Page Features of the CLI Introduction to the 3ware Command Line InterfaceTerminology Supported Operating SystemsWorking with 3ware CLI Installing the 3ware CLI on Mac OSUsing a single command with output Using the command interface interactivelyOutputting the CLI to a Text File Using an input file to execute a scriptConventions Understanding RAID Levels and ConceptsRAID Concepts RAID Available RAID ConfigurationsRAID 0 Configuration Example RAID 5 Configuration Example Single Disk Determining What RAID Level to UseUsing Drive Capacity Efficiently CLI Syntax Reference Common Tasks Mapped to CLI CommandsCommon Tasks Mapped to CLI Commands Common Tasks Mapped to CLI Commands Syntax Overview Focus Object Shell Object CommandsShow Show ver Show diag Show alarms reverseShow rebuild Show selftest Show verifyCommit Update fw=filenamewithpath forceFlush RescanCx show Controller Object CommandsCx show Typical output looks like Cx show attribute attributeCx show firmware Cx show biosCx show driver Cx show modelCx show achip Cx show serialCx show pcb Cx show pchipCx show exportjbod Cx show numportsCx show numunits Cx show ctlbusCx show autocarve Cx show spinupCx show stagger Cx show ondegradeCx show memory Cx show carvesizeCx show unitstatus Cx show autorebuildCx show drivestatus Cx show allunitstatus3JV3MVTA Cx show allSupported Stripe Sizes Controller Object Commands Supported Model-Unit Types for ignoreECC Cx rescan noscanCx commit Cx update fw=filenamewithpath forceCx flush Cx show diag Cx show alarms reverseCx show rebuild RAID-5 Initializing Cx show verify Cx show selftest Cx add rebuild=dddhhduration Setting Up a Rebuild ScheduleCx add verify=dddhhduration Setting Up a Verify ScheduleCx del rebuild=slotid Cx add selftest=dddhhCx del verify=slotid Cx set rebuild=enabledisable1..5Cx del selftest=slotid Cx set selftest=enabledisable task=UDMASMART Cx set verify=enabledisable1..5Cx set exportjbod=onoff Cx set autocarve=onoff Cx set ondegrade=cacheofffollowCx set spinup=nn Cx set stagger=nnCx set autorebuild=onoff Cx set carvesize=1024..2048Cx stop mediascan Cx start mediascanCx/ux show Unit Object CommandsCx/ux show status Cx/ux show attribute attributeCx/ux show name Cx/ux show rebuildstatusCx/ux show verifystatus Cx/ux show initializestatusCx/ux show autoverify Cx/ux show qpolicyCx/ux show storsave Cx/ux show identifyCx/ux show all Cx/ux show volumesCx/ux show cache Cx/ux show ignoreECCCx/ux del noscan quiet Cx/ux remove noscan quietCx/ux start verify Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux resume rebuild Cx/ux pause rebuildCx/ux stop verify Cx/ux set autoverify=onoff Cx/ux flushCx/ux set cache=onoff quiet Cx/ux set qpolicy=onoff Cx/ux set identify=onoffCx/ux set ignoreECC=onoff Cx/ux set name=stringCx/ux set storsave=protectbalanceperform quiet By default, qpolicy is offExample Valid Migration Paths Supported Stripe Sizes Migration Process 3JV2Q1VA Cx/px show Port Object CommandsCx/px show attribute attribute Cx/px show firmware Cx/px show statusCx/px show model Cx/px show serialCx/px show smart Cx/px show ncqCx/px show lspeed Cx/px show capacityCx/px show all Cx/px set identify=onoff Cx/px remove noscan quietCx/bbu show BBU Object CommandsCx/bbu show status Cx/bbu show attribute attributeCx/bbu show temp Cx/bbu show batinstCx/bbu show lasttest Cx/bbu show voltCx/bbu show pcb Cx/bbu show bootloaderCx/bbu show serial Cx/bbu show fwCx/bbu disable quiet Cx/bbu enableEx show Enclosure Object CommandsEx show controllers Ex show attribute attributeEx show slots Ex/slotx show Ex show fansEx show temp Ex show allEx/tempx show Ex/slotx show identifyEx/slotx set identify=onoff Ex/fanx showHelp with specific commands Help CommandsHelp with attributes Help show HelpHelp flush Help focus Help updateHelp rescan Help commitReturn Code