AMCC 9590SE-4ME manual Port Object Commands, Cx/px show attribute attribute

Page 75

Port Object Commands

Port Object Commands

Port Object Messages are commands that provide information and perform actions related to a specific disk, attached to a port, such as /c0/p0. You use port object commands for such tasks as seeing the status, model, or serial number of the drive.

Syntax

/cx/px show

/cx/px show attribute [attribute ...] where attributes are: capacityfirmwareidentify (9550SX and 9590SE only) lspeed (9550SX and 9590SE only)model

ncq (9550SX and 9590SE only)serialsmartstatus /cx/px show all

/cx/px remove [noscan][quiet]

/cx/px set identify=onoff (9550SX and 9590SE only)

/cx/px show

This command shows summary information about the specified disk attached to port /cx/px. Typical information looks like:

Example:

//localhost> /c1/p5 show

Port Status Unit Size Blocks Serial

---------------------------------------------------------

p5

OK

u0

149.05 GB 312581808

3JS0L9QW

The above report indicates that port 5 of controller 1 is attached to one l disk with status OK participating in unit 0.

/cx/px show attribute [attribute ...]

This command shows the current setting of the given attributes on the specified port or drive. One or many attributes can be requested. Specifying an invalid attribute will terminate the loop. Possible attributes are: capacity, firmware, identify (9550SX and 9590SE only), lspeed (9550SX and 9590SE only), model, ncq (9550SX and 9590SE only), serial, smart, and status.

www.3ware.com

69

Image 75
Contents 3ware Command Line InterfaceCopyright Table of Contents Page Cx/ux set autoverify=onoff Return Code About this CLI Guide Page Features of the CLI Introduction to the 3ware Command Line InterfaceTerminology Supported Operating SystemsWorking with 3ware CLI Installing the 3ware CLI on Mac OSUsing a single command with output Using the command interface interactivelyOutputting the CLI to a Text File Using an input file to execute a scriptConventions Understanding RAID Levels and ConceptsRAID Concepts RAID Available RAID ConfigurationsRAID 0 Configuration Example RAID 5 Configuration Example Single Disk Determining What RAID Level to UseUsing Drive Capacity Efficiently CLI Syntax Reference Common Tasks Mapped to CLI CommandsCommon Tasks Mapped to CLI Commands Common Tasks Mapped to CLI Commands Syntax Overview Focus Object Shell Object CommandsShow Show ver Show alarms reverse Show diagShow rebuild Show selftest Show verifyCommit Update fw=filenamewithpath forceFlush RescanCx show Controller Object CommandsCx show Typical output looks like Cx show attribute attributeCx show firmware Cx show biosCx show driver Cx show modelCx show achip Cx show serialCx show pcb Cx show pchipCx show exportjbod Cx show numportsCx show numunits Cx show ctlbusCx show autocarve Cx show spinupCx show stagger Cx show ondegradeCx show memory Cx show carvesizeCx show unitstatus Cx show autorebuildCx show drivestatus Cx show allunitstatus3JV3MVTA Cx show allSupported Stripe Sizes Controller Object Commands Supported Model-Unit Types for ignoreECC Cx rescan noscanCx update fw=filenamewithpath force Cx commitCx flush Cx show diag Cx show alarms reverseCx show rebuild RAID-5 Initializing Cx show verify Cx show selftest Cx add rebuild=dddhhduration Setting Up a Rebuild ScheduleCx add verify=dddhhduration Setting Up a Verify ScheduleCx del rebuild=slotid Cx add selftest=dddhhCx set rebuild=enabledisable1..5 Cx del verify=slotidCx del selftest=slotid Cx set verify=enabledisable1..5 Cx set selftest=enabledisable task=UDMASMARTCx set exportjbod=onoff Cx set autocarve=onoff Cx set ondegrade=cacheofffollowCx set spinup=nn Cx set stagger=nnCx set autorebuild=onoff Cx set carvesize=1024..2048Cx stop mediascan Cx start mediascanCx/ux show Unit Object CommandsCx/ux show status Cx/ux show attribute attributeCx/ux show name Cx/ux show rebuildstatusCx/ux show verifystatus Cx/ux show initializestatusCx/ux show autoverify Cx/ux show qpolicyCx/ux show storsave Cx/ux show identifyCx/ux show all Cx/ux show volumesCx/ux show cache Cx/ux show ignoreECCCx/ux del noscan quiet Cx/ux remove noscan quietCx/ux start verify Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux pause rebuild Cx/ux resume rebuildCx/ux stop verify Cx/ux flush Cx/ux set autoverify=onoffCx/ux set cache=onoff quiet Cx/ux set qpolicy=onoff Cx/ux set identify=onoffCx/ux set ignoreECC=onoff Cx/ux set name=stringCx/ux set storsave=protectbalanceperform quiet By default, qpolicy is offExample Valid Migration Paths Supported Stripe Sizes Migration Process 3JV2Q1VA Port Object Commands Cx/px showCx/px show attribute attribute Cx/px show firmware Cx/px show statusCx/px show model Cx/px show serialCx/px show smart Cx/px show ncqCx/px show lspeed Cx/px show capacityCx/px show all Cx/px set identify=onoff Cx/px remove noscan quietCx/bbu show BBU Object CommandsCx/bbu show status Cx/bbu show attribute attributeCx/bbu show temp Cx/bbu show batinstCx/bbu show lasttest Cx/bbu show voltCx/bbu show pcb Cx/bbu show bootloaderCx/bbu show serial Cx/bbu show fwCx/bbu disable quiet Cx/bbu enableEx show Enclosure Object CommandsEx show attribute attribute Ex show controllersEx show slots Ex/slotx show Ex show fansEx show temp Ex show allEx/tempx show Ex/slotx show identifyEx/slotx set identify=onoff Ex/fanx showHelp with specific commands Help CommandsHelp with attributes Help Help showHelp flush Help focus Help updateHelp rescan Help commitReturn Code