AMCC 9590SE-4ME manual Determining What RAID Level to Use, Single Disk

Page 19

Understanding RAID Levels and Concepts

Single Disk

A single drive can be configured as a unit through 3ware software. (3DM 2 or CLI). Like disks in other RAID configurations, single disks contain 3ware Disk Control Block (DCB) information and are seen by the OS as available units.

Single drives are not fault tolerant and therefore not recommended for high availability systems unless additional precautions are taken to prevent system hangs and data loss.

Hot Spare

A hot spare is a single drive, available online, so that a redundant unit can be automatically rebuilt in case of drive failure.

Determining What RAID Level to Use

Your choice of which type of RAID unit (array) to create will depend on your needs. You may wish to maximize speed of access, total amount of storage, or redundant protection of data. Each type of RAID unit offers a different blend of these characteristics.

The following table provides a brief summary of RAID type characteristics.

Table 2: RAID Configuration Types

RAID Type

Description

 

 

RAID 0

Provides performance, but no fault tolerance.

 

 

RAID 1

Provides fault tolerance and a read speed advantage over non-

 

RAID disks.

 

 

RAID 5

This type of unit provides performance, fault tolerance, and high

 

storage efficiency.

 

 

RAID 10

A combination of striped and mirrored units for fault tolerance

 

and high performance.

 

 

Single Disk

Not a RAID type, but supported as a configuration.

 

Provides for maximum disk capacity with no redundancy.

 

 

You can create one or more units, depending on the number of drives you have installed.

www.3ware.com

13

Image 19
Contents 3ware Command Line InterfaceCopyright Table of Contents Page Cx/ux set autoverify=onoff Return Code About this CLI Guide Page Features of the CLI Introduction to the 3ware Command Line InterfaceTerminology Supported Operating SystemsWorking with 3ware CLI Installing the 3ware CLI on Mac OSUsing a single command with output Using the command interface interactivelyOutputting the CLI to a Text File Using an input file to execute a scriptConventions Understanding RAID Levels and ConceptsRAID Concepts RAID Available RAID ConfigurationsRAID 0 Configuration Example RAID 5 Configuration Example Single Disk Determining What RAID Level to UseUsing Drive Capacity Efficiently CLI Syntax Reference Common Tasks Mapped to CLI CommandsCommon Tasks Mapped to CLI Commands Common Tasks Mapped to CLI Commands Syntax Overview Focus Object Shell Object CommandsShow Show ver Show diag Show alarms reverseShow rebuild Show selftest Show verifyCommit Update fw=filenamewithpath forceFlush RescanCx show Controller Object CommandsCx show Typical output looks like Cx show attribute attributeCx show firmware Cx show biosCx show driver Cx show modelCx show achip Cx show serialCx show pcb Cx show pchipCx show exportjbod Cx show numportsCx show numunits Cx show ctlbusCx show autocarve Cx show spinupCx show stagger Cx show ondegradeCx show memory Cx show carvesizeCx show unitstatus Cx show autorebuildCx show drivestatus Cx show allunitstatus3JV3MVTA Cx show allSupported Stripe Sizes Controller Object Commands Supported Model-Unit Types for ignoreECC Cx rescan noscanCx commit Cx update fw=filenamewithpath forceCx flush Cx show diag Cx show alarms reverseCx show rebuild RAID-5 Initializing Cx show verify Cx show selftest Cx add rebuild=dddhhduration Setting Up a Rebuild ScheduleCx add verify=dddhhduration Setting Up a Verify ScheduleCx del rebuild=slotid Cx add selftest=dddhhCx del verify=slotid Cx set rebuild=enabledisable1..5Cx del selftest=slotid Cx set selftest=enabledisable task=UDMASMART Cx set verify=enabledisable1..5Cx set exportjbod=onoff Cx set autocarve=onoff Cx set ondegrade=cacheofffollowCx set spinup=nn Cx set stagger=nnCx set autorebuild=onoff Cx set carvesize=1024..2048Cx stop mediascan Cx start mediascanCx/ux show Unit Object CommandsCx/ux show status Cx/ux show attribute attributeCx/ux show name Cx/ux show rebuildstatusCx/ux show verifystatus Cx/ux show initializestatusCx/ux show autoverify Cx/ux show qpolicyCx/ux show storsave Cx/ux show identifyCx/ux show all Cx/ux show volumesCx/ux show cache Cx/ux show ignoreECCCx/ux del noscan quiet Cx/ux remove noscan quietCx/ux start verify Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux resume rebuild Cx/ux pause rebuildCx/ux stop verify Cx/ux set autoverify=onoff Cx/ux flushCx/ux set cache=onoff quiet Cx/ux set qpolicy=onoff Cx/ux set identify=onoffCx/ux set ignoreECC=onoff Cx/ux set name=stringCx/ux set storsave=protectbalanceperform quiet By default, qpolicy is offExample Valid Migration Paths Supported Stripe Sizes Migration Process 3JV2Q1VA Cx/px show Port Object CommandsCx/px show attribute attribute Cx/px show firmware Cx/px show statusCx/px show model Cx/px show serialCx/px show smart Cx/px show ncqCx/px show lspeed Cx/px show capacityCx/px show all Cx/px set identify=onoff Cx/px remove noscan quietCx/bbu show BBU Object CommandsCx/bbu show status Cx/bbu show attribute attributeCx/bbu show temp Cx/bbu show batinstCx/bbu show lasttest Cx/bbu show voltCx/bbu show pcb Cx/bbu show bootloaderCx/bbu show serial Cx/bbu show fwCx/bbu disable quiet Cx/bbu enableEx show Enclosure Object CommandsEx show controllers Ex show attribute attributeEx show slots Ex/slotx show Ex show fansEx show temp Ex show allEx/tempx show Ex/slotx show identifyEx/slotx set identify=onoff Ex/fanx showHelp with specific commands Help CommandsHelp with attributes Help show HelpHelp flush Help focus Help updateHelp rescan Help commitReturn Code