AMCC 9590SE-4ME manual Migration Process

Page 73

Unit Object Commands

autoverify attribute enables the autoverify attribute on the unit that is to be migrated. For more details on this feature, see “/cx/ux set autoverify=onoff” on page 61.

Migration Process

In all cases of migration, the background migration process must be completed before the newly sized unit is available for use. You can continue using the original unit during this time. Once the migration is finished, a reboot will be required if you are booted from the unit. For secondary storage, depending on your operating system, you may need to first unmount the unit, then use CLI commands to ‘remove’ and ‘rescan’ the unit so that the operating system can see the new capacity, and then remount the unit. For details see “/cx/ux remove [noscan] [quiet]” on page 58 and “/cx rescan [noscan]” on page 38.

You may also need to resize the file system or add a new partition. For instructions, consult the documentation for your operating system.

Warning: It is important that you allow migration to complete before adding drives to the unit. Making physical changes to the unit during migration may cause the migration process to stop, and can jeopardize the safety of your data.

Example of splitting a mirror

//localhost> /c1/u3 migrate type=single

Indicates that u3 is a TWINSTOR or RAID-1 and the Migrate command splits u3 to u3 and ux with a RAID type of Single.

Example of capacity expansion

//localhost> /c0/u0 migrate type=raid10 disk=3-4 stripe=16

Indicates that the destination unit has a RAID type of raid10 and has the disk 3 and 4 in addition to all the disks in the existing unit u0.

Example of migrate output

The following is an example of how migrating units will be displayed. In this example, the report indicates that /c0/u0 is a migrating unit with 67% completion. The report also indicate that Source Unit su0 is of type RAID-1 and Destination Unit du0 is of type RAID-10.

www.3ware.com

67

Image 73
Contents 3ware Command Line InterfaceCopyright Table of Contents Page Cx/ux set autoverify=onoff Return Code About this CLI Guide Page Features of the CLI Introduction to the 3ware Command Line InterfaceTerminology Supported Operating SystemsWorking with 3ware CLI Installing the 3ware CLI on Mac OSUsing a single command with output Using the command interface interactivelyOutputting the CLI to a Text File Using an input file to execute a scriptConventions Understanding RAID Levels and ConceptsRAID Concepts RAID Available RAID ConfigurationsRAID 0 Configuration Example RAID 5 Configuration Example Single Disk Determining What RAID Level to UseUsing Drive Capacity Efficiently CLI Syntax Reference Common Tasks Mapped to CLI CommandsCommon Tasks Mapped to CLI Commands Common Tasks Mapped to CLI Commands Syntax Overview Focus Object Shell Object CommandsShow Show ver Show diag Show alarms reverseShow rebuild Show selftest Show verifyFlush Update fw=filenamewithpath forceRescan CommitCx show Controller Object CommandsCx show Typical output looks like Cx show attribute attributeCx show driver Cx show biosCx show model Cx show firmwareCx show pcb Cx show serialCx show pchip Cx show achipCx show numunits Cx show numportsCx show ctlbus Cx show exportjbodCx show stagger Cx show spinupCx show ondegrade Cx show autocarveCx show memory Cx show carvesizeCx show unitstatus Cx show autorebuildCx show drivestatus Cx show allunitstatus3JV3MVTA Cx show allSupported Stripe Sizes Controller Object Commands Supported Model-Unit Types for ignoreECC Cx rescan noscanCx commit Cx update fw=filenamewithpath forceCx flush Cx show diag Cx show alarms reverseCx show rebuild RAID-5 Initializing Cx show verify Cx show selftest Cx add rebuild=dddhhduration Setting Up a Rebuild ScheduleCx add verify=dddhhduration Setting Up a Verify ScheduleCx del rebuild=slotid Cx add selftest=dddhhCx del verify=slotid Cx set rebuild=enabledisable1..5Cx del selftest=slotid Cx set selftest=enabledisable task=UDMASMART Cx set verify=enabledisable1..5Cx set exportjbod=onoff Cx set spinup=nn Cx set ondegrade=cacheofffollowCx set stagger=nn Cx set autocarve=onoffCx set autorebuild=onoff Cx set carvesize=1024..2048Cx stop mediascan Cx start mediascanCx/ux show Unit Object CommandsCx/ux show status Cx/ux show attribute attributeCx/ux show verifystatus Cx/ux show rebuildstatusCx/ux show initializestatus Cx/ux show nameCx/ux show storsave Cx/ux show qpolicyCx/ux show identify Cx/ux show autoverifyCx/ux show cache Cx/ux show volumesCx/ux show ignoreECC Cx/ux show allCx/ux del noscan quiet Cx/ux remove noscan quietCx/ux start verify Cx/ux start rebuild disk=pp-p...ignoreECCCx/ux resume rebuild Cx/ux pause rebuildCx/ux stop verify Cx/ux set autoverify=onoff Cx/ux flushCx/ux set cache=onoff quiet Cx/ux set ignoreECC=onoff Cx/ux set identify=onoffCx/ux set name=string Cx/ux set qpolicy=onoffCx/ux set storsave=protectbalanceperform quiet By default, qpolicy is offExample Valid Migration Paths Supported Stripe Sizes Migration Process 3JV2Q1VA Cx/px show Port Object CommandsCx/px show attribute attribute Cx/px show model Cx/px show statusCx/px show serial Cx/px show firmwareCx/px show lspeed Cx/px show ncqCx/px show capacity Cx/px show smartCx/px show all Cx/px set identify=onoff Cx/px remove noscan quietCx/bbu show BBU Object CommandsCx/bbu show status Cx/bbu show attribute attributeCx/bbu show lasttest Cx/bbu show batinstCx/bbu show volt Cx/bbu show tempCx/bbu show serial Cx/bbu show bootloaderCx/bbu show fw Cx/bbu show pcbCx/bbu disable quiet Cx/bbu enableEx show Enclosure Object CommandsEx show controllers Ex show attribute attributeEx show slots Ex show temp Ex show fansEx show all Ex/slotx showEx/slotx set identify=onoff Ex/slotx show identifyEx/fanx show Ex/tempx showHelp with specific commands Help CommandsHelp with attributes Help show HelpHelp flush Help rescan Help updateHelp commit Help focusReturn Code