Shell Object Commands
(Not Optimal) state, RRate (Rebuild Rate) of 2, VRate (Verify Rate) of 5, BBU of
PAUSED, REBUILDING,
For a system with an enclosure unit such as the 3ware Sidecar that includes support for an EPCT (Enclosure Port Configuration Table), applicable firmware and software, and an appropriate controller (9550SX, 9590SE, or 9650SE), a global view of the environment also includes summary information about detected enclosures.
Example:
Typical output of the Show command for a system with an enclosure looks like the following:
//localhost> show
Ctl Model Ports Drives Units NotOpt RRate VRate BBU
c0 | 4 | 2 | 1 | 0 | 4 | 4 | - | ||
Encl | Slots | Drives | Fans | TSUnits |
| Ctls |
|
|
|
|
|
| |||||||
e0 | 4 | 2 | 1 | 1 |
| 1 |
|
|
|
The output above shows the enclosure summary information with the name of the enclosure, the protocol used, the number of drive slots, the number of drives, the number of fans, the number of temperature sensors, and the number of controllers that are associated with the enclosure.
show ver
This command will show the CLI and API version.
Example:
//localhost> show ver CLI Version = 2.00.00.0xx API Version = 2.00.00.0xx
where xx is the actual version. See the Release Notes for details.