Installation
System Wiring
NOTICE
Do not connect any of the SW+ (13,9,5,1) and SW- (16,12,8,4) pins together, either directly or via a switch closure. Doing so will create a short circuit condition which will disable and potentially damage the controller.
NOTE: On an AC controller (p/n 24B596), the J7 strip is line (input) voltage but the J6 strip is all 24VDC. On a DC controller (p/n 24B59‘), the J6 and J7 terminals all carry the input voltage.
Input Sensor Wiring:
DRY CONTACT SWITCH  | SINK SWITCH - 2 or 3 Wire Type  | 
J6  | J6  | 
 4 (SW 
 3 (SEN (x))
 2 (IN (x))
![]()
![]()
![]()
 1 (SW +) x = sensor input 1,2,3 or 4
 4 (SW 
 3 (SEN (x))
 2 (IN (x))
 1 (SW +)
FIG. 8
FIG. 10
SOURCE SWITCH - 2 or 3 Wire Type
x = sensor input 1,2,3 or 4
J6
 4 (SW 
 3 (SEN (x))
 2 (IN (x))
 1 (SW +)
x = sensor input 1,2,3 or 4
FIG. 9
313855H  | 11  |