Graco 24B596, 24B591 Display Setup, Quick Cycle Setup, Display Backlight

Page 26

Setup

DISPLAY Setup

FIG. 46

1.Use the UP/DOWN Arrow keys to move the cursor over DISPLAY.

2.Press ENTER to display the DISPLAY setup screen.

Display Backlight

The display backlight can be set to turn off after a pro- grammed amount of time. If the backlight is OFF it will turn back on when any front panel key is pressed.

FIG. 47

1.Use the Arrow keys to move the cursor over the TIMER pull-down menu.

2.From the pull-down menu, select ON.

3.Press ENTER.

4.Use the Arrow keys to move the cursor over the TIME ON field.

FIG. 48

NOTE: Time is displayed in HH:MM.

5.Use the UP/DOWN arrows to move up and down through the numbers 0-9 until the first number in the TIME ON is displayed in the field.

6.Use the RIGHT arrow to move the cursor to the next field. Repeat step 5.

7.Repeat steps 5 and 6 until the desired time displays.

8.Press RESET. The Main Screen, page 18 displays.

QUICK CYCLE Setup

FIG. 49

1.Use the UP/DOWN Arrow keys to move the cursor over QUICK CYCLE.

2.Press ENTER to display the QUICK CYCLE setup screen.

26

313855H

Image 26
Contents Important Safety Instructions GLC Lubrication ControllerElectric Shock Hazard Keypad, Display, and Icons Run Mode FunctionsComponent Identification Direction ArrowsIcons Installation Typical InstallationInstalling the Lubrication Controller GroundingSensor Wiring Configurations System Configuration and WiringSystem Configurations Modes of Operation Optional I/O Wiring DiagramsSystem Configuration Divider Valve SystemDual Line System Injector System Source Switch 2 or 3 Wire Type System WiringInput Sensor Wiring Pump on = Time Pump OFF = Time 30VDCDry Contact, shown. For other configuration, see or FIG Pump on = Cycle or Pressure Pump OFF = TimePump on = Cycle or Pressure Pump OFF = Machine Count System Wiring Options 100/240VAC System Wiring Options Alarm Out30VDC See Electric Connection Warning, SetupSystem Setup PIN Mode Enabled Timer Setup System SetupPump on Setup Main ScreenPressure Setup Cycle END SetupTo Set the Pump OFF Option Pump OFF SetupCycle Mode Selection If Both is selected If Time is selectedIf Count is selected Power UP Setup Power Up can be programmed one of four waysThird At Power Up, immediately go to Pump on normal on time Pulsed Setup Pulsed Pump ScreenPIN Setup To enable PIN Code EntryDisplay Backlight Display SetupQuick Cycle Setup LOW Level Filtering Setup Quick Cycle Screen SetupLow Level Filtering Screen Setup Run Mode Screen IdentificationPump On Ended with Time Prelube Power UpPump On Ended with Pressure Pump Off Ended with Machine Counts Pump On Ended with Cycle Switch ActivationPump Off Ended with Time Alarms Screen Pump Off Ended with Machine Counts Max Time EnteredDescription Problem Solution TroubleshootingProgram Settings Modes of OperationTechnical Data IP69KDimensions Mounting Hole LayoutGraco Standard Warranty Graco Information