Graco 24B596, 24B591 important safety instructions Technical Data, IP69K

Page 34

Technical Data

Technical Data

Input Contact

 

 

 

Power Source DC - model 24B591

9 - 30 VDC

 

 

Power Source AC - model 24B596

100 VAC to 240 VAC - 50/60 Hz

 

 

Power consumption

24 Watts

 

 

Cycle Pressure Control Input (optional)

Normally open pressure or cycle switch

 

 

Machine Count Control Input (optional)

Machine count control switch

 

 

Lubrication level (optional)

Normally open level switch, closes upon low level

 

 

Remote Manual Run Input

Normally open remote manual run switch

 

 

Outputs

 

 

 

Pump control

Pump Control Voltage = Power Source

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 100 VDC

 

 

Max Switching Current

10 A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @ 5 VDC

 

 

Low Level Alarm, normally open (optional)

 

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 30 VDC

 

 

Max Switching Current

5A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @ 5 VDC

 

 

Auxiliary Alarm, normally open (optional)

 

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 30 VDC

 

 

Max Switching Current

5A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @5 VDC

 

 

Status OK, normally open (optional)

Voltage-free Contact

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 100 VDC

 

 

Max Switching Current

10 A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @ 5 VDC

 

 

Protection grade

IP69K

 

 

Enclosure Material

Fiberglass reinforced polyester

 

 

Membrane Material

Polyester

 

 

Bushing

Ethylene Propylene Diene Monemer Rubber (EDPM)

 

 

Operating temperature range

- 40°F to 145°F (- 40°C to 63°C)

 

 

Storage Temperature

- 13°F to 145°F (- 25°C to 63°C)

 

 

34

313855H

Image 34
Contents Important Safety Instructions GLC Lubrication ControllerElectric Shock Hazard Keypad, Display, and Icons Run Mode FunctionsComponent Identification Direction ArrowsIcons Installation Typical InstallationInstalling the Lubrication Controller GroundingSensor Wiring Configurations System Configuration and WiringSystem Configurations Modes of Operation Optional I/O Wiring DiagramsSystem Configuration Divider Valve SystemDual Line System Injector System Input Sensor Wiring System WiringSource Switch 2 or 3 Wire Type Pump on = Time Pump OFF = Time 30VDCDry Contact, shown. For other configuration, see or FIG Pump on = Cycle or Pressure Pump OFF = TimePump on = Cycle or Pressure Pump OFF = Machine Count System Wiring Options 30VDC System Wiring Options Alarm Out100/240VAC System Setup PIN Mode Enabled SetupSee Electric Connection Warning, Timer Setup System SetupPump on Setup Main ScreenPressure Setup Cycle END SetupCycle Mode Selection Pump OFF SetupTo Set the Pump OFF Option If Count is selected If Time is selectedIf Both is selected Power UP Setup Power Up can be programmed one of four waysThird At Power Up, immediately go to Pump on normal on time Pulsed Setup Pulsed Pump ScreenPIN Setup To enable PIN Code EntryQuick Cycle Setup Display SetupDisplay Backlight LOW Level Filtering Setup Quick Cycle Screen SetupLow Level Filtering Screen Setup Run Mode Screen IdentificationPump On Ended with Pressure Prelube Power UpPump On Ended with Time Pump Off Ended with Time Pump On Ended with Cycle Switch ActivationPump Off Ended with Machine Counts Alarms Screen Pump Off Ended with Machine Counts Max Time EnteredDescription Problem Solution TroubleshootingProgram Settings Modes of OperationTechnical Data IP69KDimensions Mounting Hole LayoutGraco Standard Warranty Graco Information