Graco 24B596, 24B591 important safety instructions Low Level Filtering Screen Setup

Page 28

Setup

Low Level Filtering Screen Setup

The Low Level Filtering screen setup is used to filter out spurious signals from rotating paddle type low level sen- sors.

NOTE: When using the GLC4400 with the G3 Automatic Lubrication Pump, it is recommended that the low level filtering be set to G3 defaults.

The NUMBER field determines how many signal activa- tions are required to set a fault.

The TIME field determines the amount of RUN time required without an activation to reset the activation count to 0 (zero).

8.Use the RIGHT arrow to move the cursor to the next field. Repeat step 7.

9.Repeat steps 7 and 8 until the desired time is dis- played.

10.Press ENTER.

11.If the default values for the G3 Automatic Lubrica- tion Pump are intended to be used, use the UP/DOWN arrows to move to the G3 DEFAULT field.

12.Press ENTER. The NUMBER and TIME values will be updated to the G3 default value.

13.Press RESET. The Main Screen, shown on page 18, displays.

FIG. 52

1.Use the Arrow keys to move the cursor over the NUMBER field.

2.Press ENTER.

3.Use the UP/DOWN arrows to move up and down through the numbers 0-9 until the first number you want in the NUMBER field is displayed.

4.Use the RIGHT arrow to move the cursor to the next field. Repeat step 3.

NOTE: The maximum number of Counts you can setup in this field is 99.

5.Use the Arrow keys to move the cursor over the TIME field.

6.Press ENTER.

NOTE: Time is displayed in HH:MM:SS.

7.Use the UP/DOWN arrows to move up and down through the numbers 0-9 until the first number in the TIME field is displayed.

28

313855H

Image 28
Contents Important Safety Instructions GLC Lubrication ControllerElectric Shock Hazard Run Mode Functions Component IdentificationKeypad, Display, and Icons Direction ArrowsIcons Installation Typical InstallationInstalling the Lubrication Controller GroundingSystem Configuration and Wiring System Configurations Modes of OperationSensor Wiring Configurations Optional I/O Wiring DiagramsSystem Configuration Divider Valve SystemDual Line System Injector System Input Sensor Wiring System WiringSource Switch 2 or 3 Wire Type Pump on = Time Pump OFF = Time 30VDCDry Contact, shown. For other configuration, see or FIG Pump on = Cycle or Pressure Pump OFF = TimePump on = Cycle or Pressure Pump OFF = Machine Count System Wiring Options 30VDC System Wiring Options Alarm Out100/240VAC System Setup PIN Mode Enabled SetupSee Electric Connection Warning, System Setup Pump on SetupTimer Setup Main ScreenPressure Setup Cycle END SetupCycle Mode Selection Pump OFF SetupTo Set the Pump OFF Option If Count is selected If Time is selectedIf Both is selected Power UP Setup Power Up can be programmed one of four waysThird At Power Up, immediately go to Pump on normal on time Pulsed Setup Pulsed Pump Screen PIN Setup To enable PIN Code EntryQuick Cycle Setup Display SetupDisplay Backlight LOW Level Filtering Setup Quick Cycle Screen SetupLow Level Filtering Screen Setup Run Mode Screen IdentificationPump On Ended with Pressure Prelube Power UpPump On Ended with Time Pump Off Ended with Time Pump On Ended with Cycle Switch ActivationPump Off Ended with Machine Counts Alarms Screen Pump Off Ended with Machine Counts Max Time EnteredTroubleshooting Program SettingsDescription Problem Solution Modes of OperationTechnical Data IP69KDimensions Mounting Hole LayoutGraco Standard Warranty Graco Information