Graco 24B591, 24B596 important safety instructions Pressure Setup, Cycle END Setup

Page 19

7.Press ENTER.

8.Select TIMER from the pull-down list.

9.Press RESET. The Main Screen displays.

NOTE: When TIMER is selected, the Timer Icon will dis- play on the top right corner of the screen.

PRESSURE Setup

FIG. 25

NOTE: Time is displayed in HH:MM:SS.

1.Use the Arrow keys to move the cursor over the PUMP ON time box.

2.Press ENTER.

3.Use the UP/DOWN arrows to move up and down through the numbers 0-9 until the first number in the PUMP ON time is displayed in the field.

4.Use the RIGHT arrow to move the cursor to the next field.

5.Repeat steps 3 and 4 until the desired time is dis- played.

6.Use the Arrow keys to move the cursor over the ENDED BY pull-down list.

7.Press ENTER.

8.Select PRESSURE from the pull-down list.

9.Press RESET. The Main Screen, page 18 displays.

NOTE: When PRESSURE is selected, the Pressure Icon will display on the top right corner of the screen.

Setup

CYCLE END Setup

FIG. 26

NOTE: Time is displayed in HH:MM:SS.

1.Use the Arrow keys to move the cursor over the PUMP ON time box.

2.Press ENTER.

3.Use the UP/DOWN arrows to move up and down through the numbers 0-9 until the first number in the PUMP ON time is displayed in the field.

4.Use the RIGHT arrow to move the cursor to the next field.

5.Repeat steps 3 and 4 until the desired time is dis- played.

6.Use the Arrow keys to move the cursor over the ENDED BY pull-down list.

7.Press ENTER.

8.Select CYCLE from the pull-down list.

9.Press ENTER.

313855H

19

Image 19
Contents GLC Lubrication Controller Important Safety InstructionsElectric Shock Hazard Direction Arrows Run Mode FunctionsComponent Identification Keypad, Display, and IconsIcons Typical Installation InstallationGrounding Installing the Lubrication ControllerOptional I/O Wiring Diagrams System Configuration and WiringSystem Configurations Modes of Operation Sensor Wiring ConfigurationsDivider Valve System System ConfigurationDual Line System Injector System Input Sensor Wiring System WiringSource Switch 2 or 3 Wire Type 30VDC Pump on = Time Pump OFF = TimePump on = Cycle or Pressure Pump OFF = Time Dry Contact, shown. For other configuration, see or FIGPump on = Cycle or Pressure Pump OFF = Machine Count System Wiring Options 30VDC System Wiring Options Alarm Out100/240VAC System Setup PIN Mode Enabled SetupSee Electric Connection Warning, Main Screen System SetupPump on Setup Timer SetupCycle END Setup Pressure SetupCycle Mode Selection Pump OFF SetupTo Set the Pump OFF Option If Count is selected If Time is selectedIf Both is selected Power Up can be programmed one of four ways Power UP SetupThird At Power Up, immediately go to Pump on normal on time Pulsed Pump Screen Pulsed SetupTo enable PIN Code Entry PIN SetupQuick Cycle Setup Display SetupDisplay Backlight Quick Cycle Screen Setup LOW Level Filtering SetupLow Level Filtering Screen Setup Screen Identification Run ModePump On Ended with Pressure Prelube Power UpPump On Ended with Time Pump Off Ended with Time Pump On Ended with Cycle Switch ActivationPump Off Ended with Machine Counts Pump Off Ended with Machine Counts Max Time Entered Alarms ScreenModes of Operation TroubleshootingProgram Settings Description Problem SolutionIP69K Technical DataMounting Hole Layout DimensionsGraco Information Graco Standard Warranty