Graco 24B591, 24B596 important safety instructions Run Mode, Screen Identification

Page 29

Run Mode

Run Mode

When you first turn the Lubrication Controller power on, the identification screen shown in FIG. 53 displays.

A

C D

A

B

C

D

FIG. 53

B

 

FIG. 54

 

 

 

 

 

 

 

 

 

ADisplay Contrast Adjustment: UP and DOWN Arrows can be used to adjust the display contrast.

BBacklight Brightness Adjustment: LEFT and RIGHT Arrows can be used to adjust the backlight brightness.

NOTE: Contrast and Brightness adjustments can be made on any Run Screen at any time.

CSoftware (Part Number): 15Y354

D(Software) Version: 1.01.XX

Screen Identification

The following screen is only shown as an example of the information that is displayed on a Run screen. A com- plete description of the icons and symbols shown in FIG. 54 is provided on page 3.

AOperating Mode Identification - Sets up Pump On/ Pump Off, page 22.

BTime Counter - Actual elapsed time counts down while the pump runs - set up in Pump On Setup, page 18.

CProgression Bar - Real-time, visual representation of the elapsed time the pump has been on. Runs in conjunction with B.

DTotal Pump On Time - Shows the total amount of time the pump is on. Setup on the Pump On setup screen, page 18.

313855H

29

Image 29
Contents GLC Lubrication Controller Important Safety InstructionsElectric Shock Hazard Component Identification Run Mode FunctionsKeypad, Display, and Icons Direction ArrowsIcons Typical Installation InstallationGrounding Installing the Lubrication ControllerSystem Configurations Modes of Operation System Configuration and WiringSensor Wiring Configurations Optional I/O Wiring DiagramsDivider Valve System System ConfigurationDual Line System Injector System Source Switch 2 or 3 Wire Type System WiringInput Sensor Wiring 30VDC Pump on = Time Pump OFF = TimePump on = Cycle or Pressure Pump OFF = Time Dry Contact, shown. For other configuration, see or FIGPump on = Cycle or Pressure Pump OFF = Machine Count System Wiring Options 100/240VAC System Wiring Options Alarm Out30VDC See Electric Connection Warning, SetupSystem Setup PIN Mode Enabled Pump on Setup System SetupTimer Setup Main ScreenCycle END Setup Pressure SetupTo Set the Pump OFF Option Pump OFF SetupCycle Mode Selection If Both is selected If Time is selectedIf Count is selected Power Up can be programmed one of four ways Power UP SetupThird At Power Up, immediately go to Pump on normal on time Pulsed Pump Screen Pulsed SetupTo enable PIN Code Entry PIN Setup Display Backlight Display Setup Quick Cycle Setup Quick Cycle Screen Setup LOW Level Filtering SetupLow Level Filtering Screen Setup Screen Identification Run ModePump On Ended with Time Prelube Power UpPump On Ended with Pressure Pump Off Ended with Machine Counts Pump On Ended with Cycle Switch ActivationPump Off Ended with Time Pump Off Ended with Machine Counts Max Time Entered Alarms ScreenProgram Settings TroubleshootingDescription Problem Solution Modes of OperationIP69K Technical DataMounting Hole Layout DimensionsGraco Information Graco Standard Warranty