Graco 24B596, 24B591 important safety instructions Electric Shock Hazard

Page 2

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local and national codes and regulations.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu- facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

2

313855H

Image 2
Contents Important Safety Instructions GLC Lubrication ControllerElectric Shock Hazard Keypad, Display, and Icons Run Mode FunctionsComponent Identification Direction ArrowsIcons Installation Typical InstallationInstalling the Lubrication Controller GroundingSensor Wiring Configurations System Configuration and WiringSystem Configurations Modes of Operation Optional I/O Wiring DiagramsSystem Configuration Divider Valve SystemDual Line System Injector System Source Switch 2 or 3 Wire Type System WiringInput Sensor Wiring Pump on = Time Pump OFF = Time 30VDCDry Contact, shown. For other configuration, see or FIG Pump on = Cycle or Pressure Pump OFF = TimePump on = Cycle or Pressure Pump OFF = Machine Count System Wiring Options 100/240VAC System Wiring Options Alarm Out30VDC See Electric Connection Warning, SetupSystem Setup PIN Mode Enabled Timer Setup System SetupPump on Setup Main ScreenPressure Setup Cycle END SetupTo Set the Pump OFF Option Pump OFF SetupCycle Mode Selection If Both is selected If Time is selectedIf Count is selected Power UP Setup Power Up can be programmed one of four waysThird At Power Up, immediately go to Pump on normal on time Pulsed Setup Pulsed Pump ScreenPIN Setup To enable PIN Code EntryDisplay Backlight Display SetupQuick Cycle Setup LOW Level Filtering Setup Quick Cycle Screen SetupLow Level Filtering Screen Setup Run Mode Screen IdentificationPump On Ended with Time Prelube Power UpPump On Ended with Pressure Pump Off Ended with Machine Counts Pump On Ended with Cycle Switch ActivationPump Off Ended with Time Alarms Screen Pump Off Ended with Machine Counts Max Time EnteredDescription Problem Solution TroubleshootingProgram Settings Modes of OperationTechnical Data IP69KDimensions Mounting Hole LayoutGraco Standard Warranty Graco Information